Programming instructions

29
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282
XR200 Programming Guide
Additional Zone Programming
The remaining Zone Information you need to specify varies with the different Zone Types.
Below is a list of the remaining information needed and the section numbers:
If Zone Type Remaining Information Section Numbers
Exit Prewarn addresses/Entry Delay Sections 13.15 to 13.16
Fire, Supervisory, Retard and Presignal addresses Sections 13.17 to 13.18
Auxiliary 1 and 2
13.14 PREWARN ADDRESSES
At the start of the entry delay, all keypad addresses selected here display ENTER CODE:-. If
you want the prewarn to sound at all eight addresses, leave the default as shown.
To delete an address, press the matching number on the keypad. To disable prewarning at
all keypads, press a top row key to clear the addresses shown. Press the COMMAND key
when the address selection is complete.
13.15 ENTRY DELAY
Select the entry timer for this zone. Entry timers 1 to 4 are programmed in section 7.3.
13.16 ZONE RETARD
When you select YES, the zone operates with the retard delay specified in section 7.5. The
retard functions only in zone short conditions.
The zone must remain shorted for the full length of the retard delay before the panel
recognizes its condition. If you select NO, the zone operates without a retard delay.
13.17 PRESIGNAL ADDRESSES
You can enable any combination of keypad addresses to sound a presignal tone during the
time a zone is in retard delay. The presignal tone silences when the zone restores or the
retard delay expires.
To enable a presignal address, press any top row SELECT key followed by the number of the
keypad address. You can enable the presignal for all eight keypad addresses. To disable a
presignal address press the matching number digit again. Press the COMMAND key when
the address selection is complete. The Presignal prompt is only displayed when Retard is
selected as YES.
PREWARN: 12345678
RETARD NO
ENTRY DELAY: 1
PRESGNL: NONE
13 - ZONE INFORMATION