Programming instructions
23
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282
XR200 Programming Guide
12.15 AUTOMATIC ARMING
Select YES to allow this area to arm automatically according to permanent, temporary, or
extended schedules. If no schedules are programmed, the area will auto arm every hour.
If closing check is selected as YES, the automatic arming function does not take place until
the expiration of a ten minute Closing Check delay. See section 12.7. If the area has been
disarmed outside of any permanent or temporary schedule, the closing check sequence
occurs one hour after the area is disarmed.
At arming, bad zones are handled according to the option selected in section 12.16. If a
closing report is sent, the user number is indicated as SCH on the SCS-1 Receiver. NO
disables automatic arming for this area.
12.16 BAD ZONES
At the time of automatic arming, some zones in the area may not be in a normal condition.
This option allows you to program the panel's response to these bad zones. This option is not
displayed if AUTO ARM is NO.
BYP - All bad zones are bypassed. A report of the bypass is sent to the receiver if Bypass
Reports is YES. See section 6.4. The report indicates SCH as the user number.
FORC - All bad zones are force armed. Zones force armed in a bad condition are capable of
restoring and reporting an alarm if tripped. A report of the forced zone is transmitted if Bypass
Reports is YES. See section 6.4. The report indicates SCH as the user number.
REF - The automatic arming is refused and no arming takes place. A No Closing report is sent
to the receiver regardless of the Closing Check selection. See section 12.7.
12.17 AUTOMATIC DISARMING
NO disables automatic disarming by schedule for this area. When YES is selected, the area
automatically disarms according to permanent or temporary schedules. If an opening report is
sent to the receiver, the user number is indicated as SCH.
12.18 ARMED OUTPUT NUMBER
Enter the output to turn on when this area is armed. The output is turned off when this area is
disarmed. The output cannot be turned on from the Outputs On/Off option of the User Menu.
12.19 BANK SAFE AND VAULT
NO disables the Bank Safe and Vault feature for this area. When selected as YES, schedules
set for this area and the time of day cannot be changed while the area is armed.
Program schedules before arming:
A Bank Safe and Vault area can only be disarmed
during scheduled times. If you arm the area before programming a schedule, the panel must
be reset before the area can be disarmed manually from a keypad or the Bank Safe and Vault
option in Zone Programming turned to NO.
Zones in areas programmed for Bank Safe and Vault cannot be bypassed or force armed.
12.20 COMMON AREA
Select YES to enable this area to operate as a common area. This area is armed when the
last area in the partition is armed and is disarmed when the first area in the partition is
disarmed. You can have multiple common areas in each partition.
12 - AREA INFORMATION
BANK/SAF NO
BYP FORC REF
BAD ZONES: BYP
AUTO ARM NO
AUTO DIS NO
COMMON NO
OUTPUT NO: 0