Programming instructions
21
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282
XR200 Programming Guide
HOME/AWAY - in which three areas can be used: Perimeter, Interior, and Bedrooms. If you
assign zones to the Bedrooms area, the keypad display shows HOME SLEEP AWAY when
the user goes to arm the system. If you do not assign zones to the Bedrooms area, the
keypad only displays HOME AWAY to the end user.
With the HOME SLEEP AWAY option, the user can:
1. Select HOME to arm just the perimeter.
2. Select SLEEP to arm the perimeter and interior (non bedroom areas).
3. Select AWAY to arm all three areas.
12.4 EXIT DELAY
Enter the exit delay time for all Exit type zones in this partition. When the exit delay time
starts, all activity on that zone and other non-24 hour zone types in the area are ignored until
the exit delay expires. This delay countdown is displayed on the keypad.
If an Exit zone is in a bad condition at the end of the exit delay:
• the alarm bell sounds for 15 seconds
• an Exit Error report is sent to the central station receiver
• the bad Exit zone is force armed
If any other zone type is placed in a bad condition at the end of the exit delay an alarm is
indicated. The exit delay can be from 1 to 250 seconds.
Enter zero to disable the Exit Delay feature.
12.5 BURGLARY BELL OUTPUT
Enter the output number (0 to 10, 100 to 299 or D1 to D16 if Model 485 is used) that is turned
on any time a Burglary type zone in this partition is placed in alarm. The output is turned off
when you disarm the area in which the alarm occurred and no other Burglary type zones are
in alarm. The output can also be turned off using the Alarm Silence option in the User Menu
or by entering a user code with the authority to silence alarms. The duration of this bell output
follows the time entered in the System Options/Bell Cutoff Time prompt. See section 8.2. If
Bell Test is YES (see section 8.3), the Burglary Bell Output entered here is turned on for two
seconds each time the system is armed.
12.6 OPENING/CLOSING REPORTS
This option allows an Opening report to be sent to the receiver whenever an area within this
partition is disarmed. A Closing report is also sent to the receiver when any area within this
partition is armed.
12.7 CLOSING CHECK
Select YES to enable the panel to verify that all areas in this partition have been armed after
temporary or permanent schedules have expired. If the Closing Check finds any areas
disarmed past the scheduled time, the keypad selected to display System Trouble Status
emits a steady beep and displays CLOSING TIME!.
If you select Area Schedules in section 12.10, the appropriate area name is displayed
followed by - LATE. The keypad's steady beep is silenced by pressing any top row SELECT
key. If the system is not armed or a temporary schedule not entered to extend the closing
within ten minutes, a no closing report is sent to the SCS-1 Receiver if AUTO ARM is NO.
See section 12.15. If the area has been disarmed outside of any permanent or temporary
schedule, the closing check sequence occurs one hour after the area is disarmed and
continues each hour until the area is armed or the schedule is extended.
12.8 CLOSING CODE
When YES is selected, a code number is required for system arming. If NO is selected, a
code number is not required for system arming.
12 - AREA INFORMATION
OPN/CLOS YES
CLS CHK NO
CLS CODE NO
EXIT DELAY: 45
BURG BEL OUT: 0