Programming instructions

20
XR200 Programming Guide
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282
11.1 PRINTER REPORTS
This section allows you to define the operation of a local printer connected to the panel
through the use of a DMP 462P Printer Interface Card. The 462P allows you to connect the
DMP SCS-PTR or other compatible 40 or 80 character serial printer to the XR200 panel.
Printing the panel's event buffer
The Display Events option in the User Menu contains a PRINT command that allows the user
to send the contents of the panel's event buffer to a local printer. The PRINT option is visible
whether or not a 462P Printer Interface Card is attached to the panel.
11.2 ARM AND DISARM REPORTS
Prints arming, disarming, and Late to Close reports. Includes the area number, name, and
action (armed, disarmed, or late), the user number, user name, and time and date.
11.3 ZONE REPORTS
Prints changes in the status of active zones. Includes the zone number, name, and type as
well as the action (alarm, trouble, bypass, etc.) user number (if applicable) and area name.
11.4 USER COMMAND REPORTS
Prints user code changes, outputs turned on or off (if operated by a schedule, SCH is shown
in Display Events in place of the user number), schedule changes, and User Menu functions.
11.5 DOOR ACCESS REPORTS
Prints door access activity. Includes the door number, user number and name, and the time
and date of the door access.
11.6 SUPERVISORY REPORTS
Prints System Monitor Troubles and system events. See section 10.3.
12.1 AREA INFORMATION
Allows you to assign functions to the different areas within a partition. All non-24 hour zones
must be assigned to an active area. See Zone Information in section 13.1.
You activate an area by assigning it a name. See section 12.13. A name is given to each
active area in place of a number to assist the user during arming and disarming.
12.2 PARTITION NUMBER
Enter the partition number to program. Partition 1 using area arming can have up to eight
areas on the XR200 panel. Partitions 2, 3, and 4 using area arming can each have up to four
independent areas.
This prompt is not displayed if you only entered one partition in Device Setup.
12.3 ARMING MODE
This option allows you to program how the areas in this partition operate. If the Model 485 is
used this option does not display and is automatically set to AREA. The options you can
choose are:
AREA ARMING - in which all areas of the partition can be programmed and operated
independently. Partition 1 provides up to eight areas and partitions 2 to 4 each provide up to
four areas.
ALL/PERIMETER - in which only areas one and two are activated and operate as a
perimeter and interior system only.
11 - PRINTER REPORTS
PRINTER REPORTS
ARM/DIS NO
DOOR ACS NO
SUPV MSG NO
ZONE NO
USR CMDS NO
12 - AREA INFORMATION
MODE: AREA SYS
AREA A / P H / A
AREA INFORMATION
PARTITION NO: 1