3.8 DEFER TEST TIME
Select YES to allow the programmed test report to be deferred if the panel communicates
with a receiver within the time set in Test Frequency. See section 3.9. Select NO to send the
test report as programmed regardless of previous panel communication.
3.9 TEST FREQUENCY
Allows you to set how often the panel's test report is sent to the SCS-1 receiver. Enter from 1
to 60 days. This prompt is not displayed if Defer Test Time is set to NO.
3.10 TEST TIME
Press COMMAND to show the enter test time display. Enter the time of day the panel sends
the test report to the SCS-1 Receiver. Use entries between 12:00 to 11:59 and then choose
AM or PM. When Defer Test Time is set to NO, this option allows you to program the day of
the week the test report is sent. Choose one day of the week or all days.
3.11 RECEIVER ONE PROGRAMMING
Allows you to set the options for the first receiver the XR200 panel attempts to contact when
sending reports. The panel supports communication to two receivers.
3.12 ALARM REPORTS
YES sends Abort, Alarm, Alarm Restoral, Ambush, Exit Error, and System Recently Armed
reports to this receiver.
3.13 SUPERVISORY/TROUBLE REPORTS
YES sends Supervisory, Trouble, Trouble Restoral, Force Armed, Zone Fault reports, and
Serviceman Messages to this receiver. If the Model 485 is used Access Denied Reports will
also be sent.
3.14 OPENING/CLOSING AND USER REPORTS
YES sends Opening, Closing, Door Access, Late to Close, Unauthorized Entry, Schedule
and Code changes, Zone Reset, and Zone Bypass reports by user to this receiver.
3.15 TEST REPORT
Enter YES to enable the system test report to be sent to this receiver. Reports are sent
according to the programming in sections 3.9 to 3.10.
3.16 DOOR ACCESS REPORTS
YES sends Door Access Granted reports to this receiver whenever a door access is granted
to a user. The Door Access Granted report is only sent if the keypad number has also been
selected in Access Keypads under the SYSTEM REPORTS programming.
This prompt only
appears when a Model 485 Access Control card is installed.
3.17 BACKUP REPORTING
Enter YES to enable this receiver to be a backup to the other receiver in the event the other
receiver cannot be contacted.
3.18 FIRST TELEPHONE NUMBER
This is the first number the panel dials when sending reports to this receiver. Phone numbers
can be up to 15 characters in length. You can program a three second pause in the dialing
sequence by entering the letter P. You can program a dial tone detect by entering the letter
D. These characters are counted as part of the 15 allowable characters.
Area code selection for cellular communication:
You can also enter a letter "C" in the first or second phone
number. When entered, the characters before the "C" are only used when a 2nd LINE Cellular call is being made. All
other calls made on the main phone line will only use the characters entered after the letter "C". The letter "C" is
never dialed and is recognized by the panel as a marker only.
3 - COMMUNICATION
SPV/TRBL YES
O/C USER YES
BACKUP NO
FIRST PHONE NO.
TEST RPT YES
ALARM YES
RECEIVER 1 PROG
TEST FREQ: 0
TEST TIME
0 : 0 0 A M PM
TEST DAY: ALL
DFR TEST NO
DOOR ACS NO