Programming instructions

4
XR200 Programming Guide
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282
2 - INITIALIZATION
2.1 INITIALIZATION
This function allows you to clear selected parts of the panel's program back to the factory
defaults in preparation for system programming.
A description of each selection follows:
2.2 CLEAR ALL CODES
NO - Leaves existing codes intact.
YES - Clears the user code memory and assigns the user code number 99 to the highest
user position in each partition.
2.3 CLEAR ALL SCHEDULES
NO - Leaves existing schedules intact.
YES - Clears all primary, secondary, permanent, temporary, and output schedules.
2.4 CLEAR DISPLAY EVENTS MEMORY
NO - Leaves existing event memory intact.
YES - Clears the Security Command keypad display events memory.
2.5 CLEAR ZONE INFORMATION
NO - Leaves existing zone information intact.
YES - Clears the zone information for all zones. All zones are marked * UNUSED * and must
be renamed before being able to display on any system keypad.
2.6 CLEAR AREA INFORMATION
NO - Leaves existing area information intact.
YES - Clears the area information for all areas. All areas are marked * UNUSED * and must
be renamed before being able to display on any system keypad.
2.7 CLEAR OUTPUT INFORMATION
NO - Leaves existing output information intact.
YES - Clears all programmed Output names and any output cutoff assignment.
2.8 CLEAR COMMUNICATION AND REMOTE OPTIONS
NO - Leaves existing communication and remote options intact.
YES - Clears the communication and remote options programming to factory defaults.
2.9 SET TO FACTORY DEFAULTS
NO - Leaves existing panel programming intact.
YES - Sets the remainder of the panel's programming back to the factory default selections.
INITIALIZATION
CODES? NO YES
SURE? YES NO
SCHDS? NO YES
SURE? YES NO
EVENTS? NO YES
SURE? YES NO
ZONES? NO YES
SURE? YES NO
AREAS? NO YES
SURE? YES NO
COM/RMT? NO YES
SURE? YES NO
DEFAULTS NO YES
SURE? YES NO
OUTPUTS? NO YES
SURE? YES NO
CODES? NO YES
SURE? YES NO
SCHEDS? NO YES
For each initialization section, the
Programmer provides a
NO
or
YES
option.
Selecting
NO
advances you to the next
section prompt and does not initialize
that section of the program..
Selecting
YES
advances you to a
confirmation prompt.
If you select
YES
, the panel initializes that section of the
program and advances you to the next section prompt.
If you select
NO
, the panel advances you to the next section
prompt but does not initialize that section of the program.