Installation guide

Digital Monitoring Products XR200 Installation Guide
2
INTRODUCTION
XR200 Installation Guide Digital Monitoring Products
3
INTRODUCTION
Panel Features
2.1 Description
The DMP XR200 Command Processor™ Panel is a versatile 12 VDC, combined burglary and re communicator
panel with battery backup. The XR200 provides 8 on-board burglary zones and 2 on-board 12 VDC Class B
powered zones. The powered zones have a reset capability to provide for 2-wire smoke detectors, relays,
or other latching devices. The XR200 can communicate to one or two DMP SCS-1 Receivers using multiplex,
host, or digital dialer; one or two to DMP SCS-1R using host or digital dialer; or to non-DMP receivers using
the Contact ID and Modem IIe formats.
Figure 1: Typical XR200 System Conguration
 





 

  

          
















































2.2 Expansion Zones
Up to 232 additional zones are available on the XR200 using the remote zone capability of DMP Security
Command keypads and zone expander modules. The panel’s keypad data bus supports up to eight supervised
device addresses with each address supporting up to four programmable expansion zones.
Up to 200 zones are available using the Model 460 Interface Adaptor, 462N, 462P, 462FM, 472, or 481
Interface Cards, and any combination of zone expansion modules and single zone LX-Bus™ detectors.
Note: Do not use shielded wire for LX-Bus or Keypad Bus circuits.
2.3 Relay Output Expansion
In addition to the 2 SPDT relays and 8 voltage outputs on the XR200, you can also connect up to 25 Model 716
Output Expansion modules to each LX-Bus. These modules can provide an additional 200 programmable SPDT
relays. The XR200 provides 50 Output Schedules you can use for programming the 716 to perform a variety of
annunciation and control functions. You can also assign the 716 outputs to any of the panel’s Output Options
such as Fire Alarm, Communication Fail, or Phone Trouble Outputs.
The LX-Bus™ also supports the Model 717 Graphic Annunciator Module. Each 717 module supplies 20
switched ground outputs that follow the state of their assigned zones.