Installation guide
Digital Monitoring Products  XR200 Installation Guide
14
INSTALLATION
XR200 Installation Guide  Digital Monitoring Products
15
INSTALLATION
Telephone RJ Connector
14.1  Description
Connect the panel to the public telephone network by installing a DMP 356 RJ Cable between the panel’s J3 
connector and the RJ31X or RJ38X phone jack. Set the 3-pin headers labeled J11 and J12 on the XR200 to DD 
for digital dialer, Contact ID, or Modem IIe operation or MPX for multiplex operation.
Figure 7: Phone Jack Wiring
To Telephone
Line
RJ31X or RJ38X
Phone Block
Place a jumper across
terminals 2 and 7 to
provide phone jack
supervision, if you are
note using the Dual
Phone Line Module.
1
2
3
4 5
6
7
8
Ring Tip
To Premise
Phone
Ring 1
Tip 1
14.2  FCC registration
The Model XR200 complies with FCC part 68 and is registered with the FCC. 
Registration number: CCKUSA-18660-AL-R / Ringer Equivalence: 1.1B
14.3  Notication
Registered terminal equipment must not be repaired by the user. In case of trouble, the device must be 
immediately unplugged from the telephone jack. The factory warranty provides for repairs. Registered 
terminal equipment may not be used on party lines or in connection with coin telephones. Notication must 
be given to the telephone company with the following information:
      a. The particular line(s) the service is connected to
      b. The FCC registration number
      c. The ringer equivalence
      d. The make, model, and serial number of the device
14.4  Ground Start
For ground start operation, install a DMP Model 305 Relay into socket K4. Ground start phones cannot be 
used on commercial or residential re applications.
14.5  Answering Machine Bypass
For answering machine bypass capability, install a DMP Model 305 Relay into socket K2 according to the 
Wiring Diagram in this guide. See section 3.2. The bypass function operates by detecting the frequency of 
the tone sent to the premises by the Remote Link computer. Tones emitted by fax machines or other devices 
are ignored by the panel. When the correct frequency tone is detected, the panel picks up the phone line 
and establishes communication with the calling computer.