Installation guide
Digital Monitoring Products XR200 Installation Guide
8
INSTALLATION
XR200 Installation Guide Digital Monitoring Products
9
INSTALLATION
Standby Battery Power Calculations Standby Current Alarm Current
XR200 Control Panel
Relay Outputs 1-2 (ON)
Voltage Outputs 3-10 (ON)
Active Zones 1-8
Active Zones 9-10
2-Wire Smoke Detectors
Panel Bell Output
Qty ______x
Qty ______x
Qty ______x
Qty ______x
Qty ______x
Qty ______x
80mA
30mA
5mA
1.6mA
4mA
0.1mA
______mA
______
______
______
______
______
Qty ______x
Qty ______x
Qty ______x
Qty ______x
Qty ______x
80mA
30mA
5mA
*2mA
30mA
0.1mA
1500mA
______mA
______
______
______
______
______
______mA
893/893A Dual Phone Line Module Qty ______x 30mA ______ Qty ______x 50mA ______
460 Interface Adaptor Card 7mA ______ 7mA ______
462N Network Interface Card Qty ______x 50mA ______ Qty ______x 50mA ______
462P Printer Interface Card Qty ______x 50mA ______ Qty ______x 50mA ______
472 Inovonics 900MHz Interface Card Qty ______x 85mA ______ Qty ______x 85mA ______
481 Expansion Interface Card Qty ______x 15mA ______ Qty ______x 15mA ______
485 Enhanced Access Control Expansion Card 45mA ______ 45mA ______
865 Style y or Z Notication Module Qty ______x 26mA ______ Qty ______x 85mA ______
866 Style W Notication Module Qty ______x 45mA ______ Qty ______x 75mA ______
867 LX-Bus Style W Notication Module Qty ______x 30mA ______ Qty ______x 85mA ______
630F Remote Fire Command Center Qty ______x 60mA ______ Qty ______x 92mA ______
690/690F Security Command Keypad
Annunciator (ON)
Qty ______x 77mA ______
Qty ______x 84mA
20mA
______
______
790/790F Security Command Keypad
Active Zones (EOL Installed)
Annunciator (ON)
Qty ______x 77mA
1.6mA
______
______
Qty ______x
Qty ______x
84mA
*2mA
20mA
______
______
______
791 Easy Entry Keypad
Active Zones (EOL Installed)
Annunciator (ON)
Qty ______x 100mA
1.6mA
______
______
Qty ______x
Qty ______x
100mA
*2mA
20mA
______
______
______
693/793 Easy Entry Keypad
Active Zones (EOL Installed)
Annunciator (ON)
Qty ______x 92mA
1.6mA
______
______
Qty ______x
Qty ______x
120mA
*2mA
20mA
______
______
______
770, 771 Security Command Keypads
Active Zones (EOL Installed)
Annunciator (ON)
Qty ______x
Qty ______x
100mA
1.6mA
______
______
Qty ______x
Qty ______x
100mA
*2mA
20mA
______
______
______
733 Wiegand Interface Module
Active Zones (EOL Installed)
Annunciator (ON)
Qty ______x
Qty ______x
30mA
1.6mA
______
______
Qty ______x
Qty ______x
Qty ______x
30mA
*2mA
20mA
______
______
______
736P POPIT Interface Module
Radionics Popex, POPITs, OctoPOPITs
Qty ______x
Qty ______x
25mA
___mA
______
______
Qty ______x
Qty ______x
25mA
___mA
______
______
738A Ademco Wireless Interface Module Qty ______x 75mA ______ Qty ______x 75mA ______
710 Bus Splitter/Repeater Module Qty ______x 30mA ______ Qty ______x 30mA ______
710F Fire Bus Splitter/Repeater Module Qty ______x 40mA ______ Qty ______x 40mA ______
711, 771E, 714 Zone Expansion Modules
Active Zones (EOL Installed)
Qty ______x
Qty ______x
7mA
1.6mA
______
______
Qty ______x
Qty ______x
7mA
*2mA
______
______
712-8 Zone Expansion Module
Active Zones (EOL Installed)
Qty ______x
Qty ______x
17mA
1.6mA
______
______
Qty ______x
Qty ______x
17mA
*2mA
______
______
714-8, 714-16 Zone Expansion Module
Active Zones (EOL Installed)
Qty ______x
Qty ______x
20mA
1.6mA
______
______
Qty ______x
Qty ______x
20mA
*2mA
______
______
715 Zone Expansion Module
Active Zones (EOL Installed)
2-Wire Smokes
Qty ______x
Qty ______x
Qty ______x
7mA
4mA
.1mA
______
______
______
Qty ______x
Qty ______x
Qty ______x
7mA
*30mA
.1mA
______
______
______
715-8, 715-16 Zone Expansion Modules
Active Zones (EOL Installed)
2-Wire Smokes
Qty ______x 20mA
4mA
.1mA
______
______
______
Qty ______x 20mA
*30mA
.1mA
______
______
______
716 Output Expansion Module
Active Form C Relays
Qty ______x 7mA ______ Qty ______x
Qty ______x
7mA
28mA
______
______
717 Graphic Annunciator Module
Annunciator Outputs
Qty ______x 10mA ______ Qty ______x
Qty ______x
10mA
1mA
______
______
521LX, 521LXT, SLRLX Smoke Detectors Qty ______x 8.8mA ______ Qty ______x *28mA ______
iCOM, iCOM-E Internet Alarm Routers 78.1mA ______
Aux. Powered Devices on Terminals 7 and 11
Other than Keypads and LX-Bus Modules
______mA ______mA
Total Standby
Total Standby______mA x number of Standby Hours needed
Total Alarm
______mA
______ =
______mA +
Total
Total Alarm
________mA-hours
________mA-hours
________mA-hours
X .0001
= ________Amp-hrs
______mA
Required
*Based on 10% of active zones in alarm
Cannot exceed 7.7Ah with one Model 367 Battery
Cannot exceed 15.4Ah with two Model 367 Batteries
Cannot Exceed 23.1Ah with three Model 367 Batteries
Cannot exceed 30.8Ah with four Model 367 Batteries