Programming instructions
Digital Monitoring Products XR200-485 Programming Guide
40
ZONE INFORMATION
XR200-485 Programming Guide Digital Monitoring Products
41
15.23
CRS ZONE NO YES
Cross Zone
Select YES to enable cross zoning for this zone. Cross zoning requires one or more
armed zones to fault within a programmed time before an alarm report is sent to the
receiver.
When a cross zoned zone trips, the bell action assigned to the zone activates. The
cross zone time specied in System Options begins to count down. If another cross
zoned zone in the same area faults, or if the rst zone restores and faults again
before a Sensor Reset is done, the panel sends an alarm report.
If no other cross zoned zone in the same area trips before the cross zone time
expires, the panel sends only a zone fault report to the receiver.
Cross zoning is not compatible with all zone types: You cannot enable cross zoning
for Fire verify zones or for any Fire zones that have Retard Delay enabled.
15.24
PRIORITY NO YES
Priority
Select YES to provide additional protection for the premises by requiring this zone to
be in a normal condition before its assigned area can be armed.
ZONE NO: -
ZONE NUMBER - Enter the zone number to program next. Follow each programming
prompt as it displays. If all zones are programmed, press the Back Arrow key at the
ZONE NO: – display to continue.
Note: If you programmed any wireless zones, press the Back Arrow key for the
following wireless programming. The next four prompts are for use with the FA400-
DMP Remote Wireless Receiver.
15.25
PRG XMTR? NO YES
Program Transmitter
Select YES to program wireless transmitters. Select NO to return to Zone
Information.
Note: Before programming transmitters, you must program the panel accurate
account number, which determines the transmitter House ID number. If the account
number is changed, reprogram the transmitter to reect the new House ID number.
See section Inovonics Transmitter Information in the Appendix for more information
about programming transmitters and the House ID.
15.26
CONNECT XMTR: ***
Connect Transmitter
Connect the wireless transmitter, whose zone number displays, to the Programming
Connector on the 472 Inovonics 900MHz Card using the 620 Programming Cable.
RESET THE TRANSMITTER. The keypad display prompts you for wireless transmitters
starting from the lowest zone number to the highest.
At the CONNECT XMTR: prompt, you can also press a Select key and enter in any
wireless zone number (100 to 299 or 000 for the C100 and FA100 transmitters). After
programming all transmitters, press the COMMAND key.
15.27
CONNECT FA100 P 1
Connect Command Transmitter
Connect the FA100 or FA113 you want assigned to the partition shown (P1 = Partition
1) to the 472 Card. Press the Reset button inside the transmitter housing to initiate
programming. Repeat programming for each partition. To use the Alert buttons on
the transmitter as a panic, program AMBUSH as YES in System Reports.
Additional Zone Programming
The remaining Zone Information you need to specify varies with the different Zone
Types. Below is a list of the remaining information needed:
If Zone Type Remaining Information
Exit Prewarn addresses/Entry Delay
Fire, Supervisory, A1, and A2 Retard and Presignal addresses
15.28
XMTR PROGRAMMED
Transmitter Programmed
Transmitter Programmed displays after the wireless transmitter has been successfully
programmed into the panel.