Programming instructions

Digital Monitoring Products XR200-485 Programming Guide
36
ZONE INFORMATION
XR200-485 Programming Guide Digital Monitoring Products
37
ZONE INFORMATION
15.8
AREAS: 1234
Arming Zone Area Assignment
If the zone has been programmed as an Arming Type (AR), the only information to
enter is the areas that the zone controls.
When the zone changes from normal to shorted, the programmed areas toggle
between the armed or disarmed condition. When restored to normal, no action
occurs. When the zone opens from a normal (disarmed) state, a trouble is reported.
When opened from a shorted (armed) state, an alarm is reported and the zone
is disabled until you disarm the area(s) from either a keypad or Remote Link™
computer.
To visually indicate the armed state of the area(s), you can assign an Armed Output
to individual areas and use remote LEDs at the keyswitch. The LED turns on or off to
indicate to the user the armed state of the area(s).
If any bad zones are present when the Arming zone shorts, the LED delays lighting
for 5 seconds. If during the 5-second delay the Arming zone shorts again no arming
takes place. If 5 seconds expires without the zone shorting again or restoring to
normal, the areas arm and bad zones are force armed. To allow bad zones to be
force armed, the Any Bypass option must be set to YES. If Any Bypass option is set to
NO, arming does not occur. See the Area Information - Any Bypass section. A priority
zone cannot be force armed.
15.9
STYLE:
Style
This option species the style for the arming/disarming operation. The default style
is TGL (toggle). Press any Select key to display the STYLE options. To view more
style options press the COMMAND key.
TGL ARM DIS STEP
TGL (Toggle) - When the zone changes from normal to shorted, the programmed
areas toggle between the armed or disarmed condition. When restored to normal,
no action occurs. When the zone opens from a normal (disarmed) state, a trouble is
reported. When opened from a shorted (armed) state, an alarm is reported and the
zone is disabled until you disarm the area(s) from either a keypad or Remote Link.
ARM - When the zone is shorted, the programmed areas are armed. When restored
to normal, no action occurs. When the zone opens from a normal (disarmed) state,
a trouble is reported. When opened from a shorted (armed) state, an alarm is
reported.
DIS (Disarm) - When programmed as an AREA system, a short disarms the
programmed areas. When programmed as a ALL/PERIM or HOME/AWAY system, a
short disarms ALL areas. When restored to normal, no action occurs. When the zone
opens from a normal (disarmed) state, a trouble is reported.
STEP - A short arms the areas and beeps the keypads once. A normal condition
causes no action. An open condition disarms the programmed areas and beeps the
keypads for one second.
Note: This arming style is designed for wireless arming pendants. When using an
arming/disarming keyswitch locate the keyswitch within the protected area.
MNT
MNT (Maintain) - When the zone shorts, the programmed areas are armed. When
restored to normal, the programmed areas disarm and any alarm bells silence.
When the zone opens from a normal (disarmed) state, a trouble is reported. If
opened from a shorted (armed) state, an alarm is reported and the zone is disabled
until you disarm the area(s) from either a keypad or Remote Link.