Programming instructions
Digital Monitoring Products XR200-485 Programming Guide
34
ZONE INFORMATION
XR200-485 Programming Guide Digital Monitoring Products
35
ZONE INFORMATION
Zone Information
15.1
ZONE INFORMATION
Zone Information
Zone Information allows you to dene each protection zone operation used in the
system. All protection zones, whether located on a command processor panel,
Security Command keypad, or zone expander are programmed the same way.
15.2
ZONE NO: -
Zone Number
Enter the zone number you intend to program. Available zone numbers are shown in
the table below. Press COMMAND to enter a zone name.
Note: The second zone of addresses 9 through 16 is available for programming when
using 485 rmware version 201 or higher.
Address Programming Zone Number
Panel 1-10
1 11-14
2 21-24
3 31-34
4 41-44
5 51-54
6 61-64
7 71-74
8 81-84
9 16
10 26
11 36
12 46
13 56
14 66
15 76
16 86
LX-Bus 1 100-199
LX-Bus 2 200-299
15.3
* UNUSED *
Zone Name
Zone names can have up to 16 alphanumeric characters. Each operating zone in the
system must be given a name. The name can display at the keypads during arming
and disarming so the user does not have to memorize zone numbers. Users can
associate a zone name with a particular protection point. A zone that is not part of
the system must be marked unused.
To add a zone name to the system, press any Select key and then enter up to 16
characters for the new zone name. Press COMMAND to continue.
To mark a zone unused, delete the old name by pressing a top row Select key, then
press the COMMAND key. The programmer automatically programs the name as *
UNUSED *. If you have already cleared Zone Information during Initialization, the
zones are marked * UNUSED *.