AREA INFORMATION
XR200-485 Programming Guide Digital Monitoring Products
33
AREA INFORMATION
14.19
BANK/SAF NO YES
Bank Safe & Vault (485B only)
NO disables the Bank Safe & Vault feature for this area. When selected as YES,
schedules set for this area and the time of day cannot be changed while the area is
armed.
Program schedules before arming: A Bank Safe & Vault area can only be disarmed
during scheduled times. If you arm the area before programming a schedule, the
panel must be reset before the area can be disarmed manually from a keypad or the
Bank Safe & Vault option in Zone Programming turned to NO.
Zones in areas programmed for Bank Safe & Vault cannot be bypassed or force
armed.
Do not assign Bank Safe & Vault area to an Arming zone. Arming zones can disarm
Bank Safe & Vault areas outside of a schedule.
14.20
COMMON NO YES
Common Area
Select YES to enable this area to operate as a common area. This area is armed
when the last area in the partition is armed and is disarmed when the rst area in
the partition is disarmed. You can have multiple common areas in each partition.
For the common area to work properly, do not assign the common area to any user
codes. A user code can be programmed to arm and disarm the common area from a
keypad at any time, but the common area will not function as a common area.
14.21
TWO MAN NO YES
Two Man Rule (485B only)
Select YES to enable this area to require two user code entries to disarm or allow a
door access. When a user presents a code to a keypad or reader requesting a door
access or disarm, 2ND CODE displays and requires the entry of a different user code
with at least the same authority.
NO disables the Two Man Rule for this area.