Programming instructions
Digital Monitoring Products XR200-485 Programming Guide
30
AREA INFORMATION
XR200-485 Programming Guide Digital Monitoring Products
31
AREA INFORMATION
14.7
CLS CODE NO YES
Closing Code
When YES is selected, a code number is required for system arming. If NO is
selected, a code number is not required for system arming.
14.8
ANY BYPS NO YES
Any Bypass
When YES is selected, zones can be bypassed without a code number during the
arming sequence. A code number is always required to use the Bypass Zones option
from the menu.
14.9
AREA SCH NO YES
Area Schedules
Select YES to allow each area in this partition to set its own shift schedules 1 to 4.
Enter NO to provide one set of schedules for this partition.
Note: You can only use Area Schedules with an Area or All/Perimeter system.
14.10
EARLY AMBUSH: 0
Early Morning Ambush (485B only)
Enter the number of minutes (1 to 15) before a silent alarm (Ambush S15) is sent
to the central station using the area 1 account number. Enter zero to disable this
option.
When a user code is entered to disarm area 1, the same or different user code
must be entered within the programmed number of minutes to prevent an ambush
message being sent to the receiver. The second user code must have authority to
disarm area 1 and may be entered at either the same or another keypad or reader.
The keypad does not display any indication that the ambush timer is running.
Indications can be provided by assigning an output number to Entry Out and Ambush
Out in Output Options. Entry Out turns on one minute before the timer expires and
turns off at expiration. Ambush Out turns on when the timer expires and turns off
when Sensor reset is performed.
This option only appears when using the Model 485B card.
14.11
AREA NO: -
Area Number
Enter the number of the area in this partition you are programming. In an area
system, partition 1 can have up to 8 areas. Partitions 2 to 4 can each have up to 4
areas. After entering the area number, press COMMAND to enter the area name.
14.12
* UNUSED *
Area Name
The area name can be up to 16 alphanumeric characters. All others are marked
unused. For instructions on entering alphanumeric characters see section 1.7
Entering Alpha Characters. To add an area name to the system, press any Select
key and then enter up to 16 characters for the new area name. Press COMMAND to
continue.
To mark an active area unused, delete the old name by pressing a top row Select
key, then press the COMMAND key. The programmer automatically programs
the name as *UNUSED*. If you have already cleared Area Information during
Initialization, all areas will be marked * UNUSED *. See Section 2.1 Initialization.