Programming instructions

Digital Monitoring Products XR200-485 Programming Guide
26
STATUS LIST
XR200-485 Programming Guide Digital Monitoring Products
27
STATUS LIST
Status List
11.1
STATUS LIST
Status List
This function allows you to select the zone alarms and troubles, and system monitor
troubles displayed at the keypads. The Status List function operates automatically
when the keypad is not performing any other function. Status list displays for
addresses 9 through 16 automatically show when a corresponding address 1 through
8 is entered.
The keypad stays in the Status List until the user arms or disarms or selects a menu
option. Status List alternates with the Armed Status on keypad addresses selected
in the Menu Display - Armed Status section. You can choose to have System Monitor
troubles placed in the list, the different zone types placed in the list, and at which
keypad addresses they display.
11.2
DISPLAY KEYPADS:
Display Keypads
This option denes which keypad addresses display the various status information.
Any combination of addresses can be entered to display the status items that follow.
If you do not want a particular status item to display, do not enter any addresses.
11.3
SYS TRB 12345678
System Monitor Troubles
Species the addresses where any trouble on a System Monitor displays. The System
Monitors include the following:
AC Power
Battery Power
Closing Check
Panel Box Tamper
Phone Line 1
Phone Line 2 (requires the 893 or 893A Dual Phone Line Module)
The name of the System Monitor is placed in the Status List and the keypad steady
trouble buzzer sounds. The buzzer remains on until any top row Select key is
pressed on the keypad. The name remains in the list until the condition is restored.
11.4
FIRE 12345678
Fire Zones
Species the addresses where all re zone alarms and troubles display. The zone
name displays and, if it is a trouble condition, the keypad steady trouble buzzer
sounds. The buzzer remains on until any top row Select key is pressed. The name
remains in the list until the user clears it with the Sensor Reset function.
When using the Security Command LCD Keypads or the 630F Remote Fire Command
Center, the panel provides distinct speaker tones from the keypad for Fire:
On - Fire zone alarm and Bell Output or Fire Bell Output is ON.
Off - Alarm Silence