Programming instructions

Digital Monitoring Products XR200-485 Programming Guide
22
OUTPUT OPTIONS
XR200-485 Programming Guide Digital Monitoring Products
23
OUTPUT OPTIONS
8.5.2
CUTOFF TIME: 0
Output Cutoff Time
If a Cutoff Output is assigned, enter a Cutoff Time of 1 to 99 minutes for the output
to remain on. Enter zero for continuous output.
8.5.3
COMM FAIL OUT: 0
Communication Fail Output
Enter the output number to turn on when a DD system fails to communicate on three
successive dial attempts or a MPX system does not communicate with the receiver
for 150 seconds or if the backup communication line transmits a report
To clear the output, disarm any area or select Off for the output number in the User
Menu Outputs On/Off section. Enter zero to disable this output.
8.5.4
FIRE ALR OUT: 0
Fire Alarm Output
Enter the output number to turn on when a re type zone is placed in alarm. The
output is turned off using the Sensor Reset option while no additional re type zones
are in alarm. Enter zero to disable. This output is not compatible with Cutoff
Outputs.
8.5.5
FIRE TRB OUT: 0
Fire Trouble Output
Enter the output number to turn on when any re type zone is placed in trouble,
when any supervisory type zone is placed in alarm or trouble, or when any system
monitor (AC, Battery, Phone Line 1 or Phone Line 2) is placed in trouble. The output
turns off when all re and supervisory type zones, or system monitors are restored to
normal. Enter zero to disable this output. This output is not compatible with Cutoff
Outputs.
8.5.6
AMBUSH OUT: 0
Ambush Output
Enter the output number to turn on when an Ambush code is entered at a keypad.
The output is turned off using the Sensor Reset option. Enter zero to disable.
8.5.7
ENTRY OUT: 0
Entry Output
Enter the output number to turn on at the start of the entry delay time. The output
turns off when the area is disarmed or the entry delay time expires. Enter zero to
disable.
8.5.8
EXIT OUT: 0
Exit Output
Enter the output number to turn on when an exit delay time starts in any area of the
system. The output is turned off when the area arms or when the arming is stopped.
Enter zero to disable this output.
8.5.9
READY OUT: 0
Ready Output
Enter the output number to turn on when all disarmed burglary zones are in a
normal state. The output is turned off when any disarmed burglary type zone is in a
bad state. Enter zero to disable. This output is not compatible with Cutoff Outputs.
8.5.10
PH TRBL OUT: 0
Phone Trouble Output
Enter the output number to turn on when the phone line monitor in the DMP 893/
893A detects a voltage below 3 VDC or when the short across pins 2 and 7 on the
phone block is lost. The output is turned off when phone voltage rises above 3 VDC.
Enter zero to disable this output.
8.5.11
LATE CLS OUT: 0
Late To Close Output
Enter the output number to turn on at the expiration of a Closing schedule. The
output activates simultaneously with the CLOSING TIME! keypad display. The output
is turned off when the area is armed, the Closing is extended, or the schedule is
changed. Enter zero to disable this output.