Programming instructions

Digital Monitoring Products XR200-485 Programming Guide
20
SYSTEM OPTIONS
XR200-485 Programming Guide Digital Monitoring Products
21
OUTPUT OPTIONS
Output Options
8.1
OUTPUT OPTIONS
Output Options
This function allows you to program the panel Bell Output functions and certain
Relay Output options. Dry contact relays and voltage outputs are available using the
XR200-485/485B board output harness. Refer to the XR200 Installation Guide (LT-
0197) for complete information.
8.2
BELL CUTOFF: 15
Bell Cutoff Time
Enter the maximum time from 1 to 99 minutes the Bell Output remains on. If the
Bell Output is silenced or the area is disarmed, the cutoff time resets. Enter 0 to
provide continuous bell output. The default is 15 minutes.
8.3
BELL TST NO YES
Automatic Bell Test
Select YES to turn on the Bell Output for 2 seconds each time a partition is
completely armed from a keypad. This test delays until the Closing Wait
acknowledge is received (if selected). If the Closing Wait acknowledge is not
received within 90 seconds, the bell test does not occur. Arming performed from an
Arming zone or from Remote Link™ does not activate the Bell Test.
8.4
BELL ACTION . . . . . .
Bell Action
This section denes the type of Bell Output for zone alarms. (Trouble conditions do
not activate the Bell Output.) Press COMMAND to display the default Bell Output for
each zone type. Press any Select key and enter S for a Steady Bell Output, P for a
Pulsed output, T for a Temporal Code 3 output, and N for no Bell Output.
8.4.1
FIRE TYPE: P
Fire Bell Action
Denes Bell Action for Fire Type zones. The default is P.
8.4.2
BURGLARY TYPE: S
Burglary Bell Action
Denes Bell Action for Burglary Type zones and Exit Error output. The factory
default is set at S.
8.4.3
SUPRVSRY TYPE: N
Supervisory Bell Action
Denes Bell Action for Supervisory Type zones. The default is set at N.
8.4.4
PANIC TYPE: N
Panic Bell Action
Denes Bell Action for Panic Type zones. The default is set at N.
8.4.5
EMERGNCY TYPE: N
Emergency Bell Action
Denes Bell Action for Emergency Type zones. The default is set at N.
8.4.6
AUXLRY 1 TYPE: N
Auxiliary 1 Bell Action
Denes Bell Action for Auxiliary 1 Type zones. The default is set at N.
8.4.7
AUXLRY 2 TYPE: N
Auxiliary 2 Bell Action
Denes Bell Action for Auxiliary 2 Type zones. The default is set at N.
8.5
OUTPUT ACTION . . .
Output Action
Dene the XR200-485/485B relay outputs operation. The panel provides two Form C
relays (1 and 2) and eight 12 VDC voltage outputs (3 to 10) rated at 50mA each. You
can expand the system up to 200 additional relay outputs (numbered 100 to 299)
using multiple 716 Output Expander Modules and one or two interface cards. Keypad
door strike relays can be programmed by entering D1 to D16 for addresses 1 to 16.
Also, output groups can be programmed by entering G1 to G20.
8.5.1
CO OUTS: - - - - - - - -
Cutoff Output
Outputs 1 to 8 can be entered here to turn off after a time specied in CUTOFF
TIME. To disable this option, press any Select key to clear the display then press
COMMAND. The Cutoff Output displays NONE when no outputs are selected.