Programming instructions

Digital Monitoring Products XR200-485 Programming Guide
20
SYSTEM OPTIONS
XR200-485 Programming Guide Digital Monitoring Products
21
OUTPUT OPTIONS
7.8
RST SBYP NO YES
Reset Swinger Bypass
When YES is selected, an automatically bypassed zone is reset if it remains in a
normal condition for one complete hour after being bypassed. An automatic reset
report is sent to the receiver if Bypass Reports is selected as YES.
7.9
VIDEO NO YES
Video/Alarm Verication
Selecting YES forces the panel to wait for 60 seconds after a successful
communication with a central station receiver before making any additional
communication attempts. This 60-second period can be used to allow video
transmission or alarm verication (such as 2-way voice) equipment to use the phone
line. After the 60-second timer, the panel can once again seize the phone line and
send any pending reports.
The Video option must be set to NO if any re protection is connected to the panel.
7.10
TIME CHG NO YES
Time Zone Changes
This function allows the panel to request automatic time changes from the DMP SCS-
1/SCS-1R Receiver. For the receiver to send time changes, it must be programmed
to send time changes and must be receiving time change updates from the host
automation computer at least every 24 hours. Default is YES.
HRS FROM GMT: 6
When time zone is programmed YES, enter the number (0-23) that indicates the
Greenwich Time zone (GMT) where the panel is located. The default is 6.
GMT City/Time Zone
0 London, Monrovia, Lisbon, Dublin, Casablanca, Edinburgh
1 Cape Verde Island, Azores
2 Mid-Atlantic, Fernando de Noronha
3 Buenos Aires, Georgetown, Brasilia, Rio de Janeiro
4 Atlantic Time (Canada), Caracas, La Paz, Santiago
5 Eastern Time (US, Canada) Bogota, Lima, Arequipa
6 Central Time (US, Canada), Mexico City, Saskatchewan
7 Mountain Time (US, Canada), Edmonton
8 Pacic Time (US, Canada), Tijuana
9 Alaska
10 Hawaii
11 Midway Island, Samoa
12 Fiji, Marshall Island, Wellington, Auckland, Kwajalein, Kamchatka
13 New Cadelonia
14 Guam, Sydney
15 Tokyo, Seoul
16 Hong Kong, Singapore
17 Bangkok, Hanoi
18 Dhaka, Almaty
19 Islamabad, Karachi
20 Abu Dhabi, Kazan
21 Moscow, Bagdad
22 Eastern Europe
23 Rome, Paris, Berlin
7.11
AC CYCLES: 60HZ
AC Cycles
50HZ 60HZ
This function allows you to select either a 60 Hz or 50 Hz electrical AC cycle. When
60HZ is selected, the panel operates on a 60 Hz cycle used in the USA. Select 50HZ
for the panel to operate on a 50 Hz cycle used in countries other than the USA. The
default value is 60HZ.