Programming instructions

Digital Monitoring Products XR200-485 Programming Guide
18
SYSTEM REPORTS
XR200-485 Programming Guide Digital Monitoring Products
19
SYSTEM OPTIONS
System Reports
6.1
SYSTEM REPORTS
System Reports
Select specic system reports the panel sends to the receiver.
6.2
ABORT NO YES
Abort Report
YES allows the panel to send an alarm abort report to the receiver any time an area
is disarmed after an alarm report has been sent and the Bell Cutoff Time has not
expired. No alarmed zones can still be armed. Abort reports are also sent when the
system is disarmed during Transmit Delay and the Bell Output Timer is active. If the
communication type is set to DD, a Warning: Alarm Bell Silenced report is also sent if
the alarm bell is silenced by a user.
Note: Abort reports are not sent for Fire zones, Fire Verify, or Supervisory zones.
6.3
RESTORAL: YES
Restoral Reports
This option allows you to control when and if a zone restoral report is sent to the
central station receiver. Press a Select key to display the following options:
NO YES DISARM
NO - Disables the zone restoral report option. Zones continue to operate normally
but do not send restoral reports to the receiver.
YES - Enables the zone restoral report option. Zone restorals are sent whenever a
zone restores from a trouble or alarm condition.
DISARM - Causes the panel to send restoral reports for a non-24-hour zone whenever
a zone that has restored from a trouble or alarm condition is disarmed. All 24-hour
zones send restoral reports as they restore.
6.4
BYPASS NO YES
Bypass Reports
YES allows the panel to send all zone bypasses, resets, and force arm reports to the
receiver. The bypass report includes the zone number, zone name, and the user
name and number of the individual operating the system. Reports are only sent if
O/C User in Communications is set YES for Receiver 1 or Receiver 2.
6.5
SCHD CHG NO YES
Schedule Change Reports
YES allows the panel to send all permanent and temporary, primary and secondary
schedule changes to the receiver. The report includes the day, opening time, closing
time, and the user name and number of the individual making the change. Schedule
changes made through Remote Link™ are not sent to the printer or Display Events.
Reports are only sent if O/C User in Communications is set YES for Receiver 1 or
Receiver 2. The default setting is YES.
6.6
CODE CHG NO YES
Code Change Reports
YES allows the panel to send all code additions, changes, and deletions to the
receiver. The code change report includes the user name and number added or
deleted and the user name and number of the individual making the change. Code
changes made through Remote Link™ are not sent to the printer or Display Events.
Reports are only sent if O/C User in Communications is set YES for Receiver 1 or
Receiver 2. The default setting is YES.
6.7
ACS KEY: - - - - - - - - -
Access Keypads
Enter the keypad addresses that send door access reports to the receiver. A report is
sent with each door access made from the selected keypads. Keypads at addresses
not selected still operate the door strike relay but do not send door access reports.
Reports include the user name, number, and the keypad address.
6.8
AMBUSH NO YES
Ambush
YES allows an ambush report to be sent anytime user code number 1 is entered
at a keypad. NO disables the ambush report and allows user number 1 to operate
the same as all other codes. If YES, you can program one Ambush code for each
partition in the system.