Programming instructions
Digital Monitoring Products XR200-485 Programming Guide
16
REMOTE OPTIONS
XR200-485 Programming Guide Digital Monitoring Products
17
REMOTE OPTIONS
Remote Options
5.1
REMOTE OPTIONS
Remote Options
This section allows you to enter the information needed for Remote Command/
Remote Programming operation.
5.2
RMT KEY:
Remote Key
This option allows you to enter a code of up to eight digits for use in verifying
the authority of an alarm or service receiver to perform a remote command/
programming session. The Remote Link™ program must give the correct key to the
panel before being allowed any remote functions. All panels ship from the factory
with the key preset as blank.
To enter a remote key or change the current one, press a top row Select key and
enter any combination of up to eight digits. Press COMMAND. The current key never
displays.
5.3
MFG AUTH NO YES
Manufacturer Authorization
Select YES to allow DMP Technical Support technicians to access the panel during
system service or for troubleshooting. This authorization automatically expires
within one hour.
DMP remote service is provided on a read only basis: DMP technicians can look
at the system programming and make suggestions only. Alterations can only be
accomplished by the installing company service personnel.
5.4
ARM RINGS: 0
Armed Rings
Enter the number of rings the panel counts before answering the phone line when
all areas of the system are armed. Any number from 1 to 15 can be entered. If zero
is entered, the panel does not answer the phone when all areas of the system are
armed. The default Armed Rings is 0 (zero).
5.5
DISARM RINGS: 0
Disarmed Rings
Enter the number of rings the panel counts before answering the phone line while
any areas of the system are disarmed. Any number from 1 to 15 can be entered. If
zero is entered, the panel does not answer the phone when any area of the system is
disarmed. The default number of Disarmed Rings is 0 (zero).
5.6
ALR REC NO YES
Alarm Receiver Authorization
Select YES to enable remote commands and programming to be accepted from the
alarm SCS-1/SCS-1R Receiver. The Remote Key option can also be required.
With YES selected, the panel requests the receiver key during its rst communication
with the rst SCS-1/SCS-1R Receiver. The panel retains this alarm receiver key in
memory and allows remote commands to be accepted from the alarm receiver. If an
alarm occurs during a remote connect, the alarm report is immediately sent to this
receiver only.
When NO is selected, remote commands and programming are not accepted from
the alarm SCS-1/SCS-1R Receiver.