Programming instructions

Digital Monitoring Products XR200-485 Programming Guide
2
INTRODUCTION
XR200-485 Programming Guide Digital Monitoring Products
3
INTRODUCTION
Accessing the Programmer
1. Install the reset jumper across the two J16 reset pins for two seconds. See Figure 1.
2. Remove the reset jumper and place it over just one pin for future use.
3. Enter the code 6653 (PROG) into an alphanumeric keypad set to address one. Press COMMAND.
4. The keypad displays PROGRAMMER.
You are now ready to start programming the panel.


   

  



 


 











  



 
















Figure 1: XR200-485 Panel Showing Reset
Initializing the Panel
After installing the panel, use the Initialization function to set the panel programming to its default
settings.
Note: The default user code is 99. Change this code as soon as the system is operational.
1.3 Programmer Operation
There are 16 programming sections to choose from:
Menu Item Section in this manual Menu Item Section in this manual
Initialization 2 Menu Display 10
Communication 3 Status List 11
Device Setup 4 Printer Reports 12
Remote Options 5 Host Log Reports 13
System Reports 6 Area Information 14
System Options 7 Zone Information 15
Output Options 8
Stop
16
Output Groups 9 Set Lockout Code 17
To select a section for programming, press any one of the Select keys when the name of that section
displays on the keypad. Sections 2 through 17 contain detailed instructions for each programming step.
1.4 Programmer Lockout Codes
The panel allows you to enter the programming function without entering a lockout code using steps 1
to 4 listed in Getting Started. We recommend, however, that you install a Lockout Code that restricts
programming to only those persons your company authorizes. You can do this by using the SET LOCKOUT
CODE feature in the Programmer. The Lockout Code restricts any unauthorized programming of the panel.
After resetting the panel and entering the code 6653, the keypad displays PROGRAMMER. Press COMMAND
to advance through the programming sections until SET LOCKOUT CODE is displayed (after STOP). Press
any top row Select key. The keypad displays ENTER CODE: – . Enter a 3 to 5 digit Programmer Lockout
Code and press COMMAND. The keypad displays ENTER AGAIN followed by ENTER CODE: –. Enter the same
3 to 5 digit code a second time and press COMMAND. The keypad displays CODE CHANGED.
Note: The panel will not accept a 5-digit Lockout Code higher than 65535.
The new code number must now be entered before you can access the programmer function.
Write the Lockout Code down and keep it in a secure place with access limited to only those persons
authorized by your company to program the panel. Lost Lockout Codes require the panel be sent back to
DMP for repair. You may cancel a Lockout Code by entering 00000 at the Set Lockout Code command.