User`s guide
20  XR500 User’s Guide User Menu
 System Test
System Test is used to test the battery, alarm bell or siren, and 
communi cation to a central station. The System Test function 
begins automatically as soon as you select it.
Using the System Test Function
1.  Access the User Menu.
2.  Press COMMAND until SYSTEM TEST? displays.
3.  The keypad displays SYSTEM PANICS. Press the Select key 
below SYSTEM.
3.  The System Test begins automatically and the keypad 
displays the following messages in this order:
1)  BELL SOUNDING during a two second bell test
2)  BATTERY - OKAY or BATTERY - TRBL to indicate the 
 battery condition
* 3)  TRANSMIT TEST and ATTEMPT NO : 1 during the   
 transmit test
4)  TRANSMIT OKAY or TRANSMIT FAILED to show the   
  results of the transmit test
5)  TEST END to indicate the System Test is complete.
6)  You can press the Back Arrow key to end the transmit 
test.
  * The transmit test does not operate on local systems.
Using the Panic Zone Test
1.  Access the User Menu.
2.  Press COMMAND until SYSTEM TEST? displays.
3.  Press any Select key. The keypad displays SYSTEM PANICS.
4.  Press the Select key below PANICS.
5.  The Panic Zone Test begins automatically and the keypad 
displays TRIPS: END. 
  During the Panic Zone Test, trip each panic zone (or button) 
on the system by pressing and holding the panic for 1 to 2 
seconds. 
Note: You do NOT have to hold the panic for 2 seconds in normal 
mode. You are only required to hold the panic during the 
Panic Zone Test because the zone takes additional time to 
report when the system is in test mode. 
  Each time you trip a panic zone, the display number 
increments and the keypad buzzer sounds for two seconds.
  The number of panic zones tripped constantly displays until 
the test ends or no panic zone activity has occurred for 20 
minutes. 
6.  Press the Select key below END to stop the Panic Zone 
Test.
7.  PANIC TEST OKAY displays when the Panic Zone Test is 
completed and all zones tested OK.
8.  When the Panic Zone Test ends and a zone failed (did not 
trip) during the test, the keypad displays the zone name 
and number and the buzzer sounds for one second. Press 
the COMMAND key to display the next failed zone. 
Note: During the Panic Zone Test, any zones that fail are not sent 
to the receiver or to the pager.