User`s guide
30  XR500/XR100 User’s Guide User Menu
  XR500/XR100 User’s Guide  31User Menu 
Browser Feature
Refer to Appendix B in this guide for a diagram showing you how to 
use the Change User Proles browser.
Deleting User Profiles
1.  Access the User Menu.
2.  Press COMMAND until USER PROFILES? displays.
3.  Press any Select key. The keypad displays ADD DEL CHG.
4. Select DEL to delete a user prole.
5.  At  the  PROFILE  NO:  -  option,  enter  a  prole  number  and 
press COMMAND. The display changes to DELTD.
Note: User codes assigned to deleted proles will not function. 
Browser Feature
Refer to Appendix B in this guide for a diagram showing you how to 
use the Delete User Proles browser.
TEMP CODE
When  you  select  YES  for  this  menu  option,  and  this  prole  is 
assigned to a user code (see next  section),  the  keypad  displays 
TEMP  EXPIRE  DATE:.    Enter  the  ending  date  for  the  prole  to 
expire.    Default  is  seven  days  from  today.    The  system  deletes 
Temp users at 12:00 AM on the last date.
ANTI PASS NO 
Anti-passback  requires  that  you  properly  exit  (egress)  an  area 
previously accessed.   If  you fail  to  exit through  the  proper 
location you cannot access it until you properly  exit.  Default  is 
No. See Failed to Exit (Anti-Passback) for more information.
SHIFT TIME ACCESS: 1 2 3 4 ANYTIME
This menu option denes the time schedules that the User Code 
operates for door access and disarming.  Selecting 1, 2, 3, and/or 
4 indicates operation during the S1-S4 shift schedules.  Selecting 
ANYTIME  from  the  menu  indicates  the code  operates  any  time, 
regardless of schedules.  An asterisk displays next to the shift or 
Anytime choice.  You may select all shift schedules for one user.  
Menu access  is  not  affected by this  option.   An  UNAUTHORIZED 
ENTRY message is sent to the central station if disarming occurs 
outside the open/close schedule. 
RE ARM DELAY 
RE ARM DELAY allows the entry of 0 to 250 minutes to be used to 
delay automatic rearming when the user disarms an area outside 
of  schedule.   If  zero  is selected,  the  rearming  occurs  based on 
permanent programming in the panel. 
RE ARM DELAY is also used to delay a late to close message to the 
central station when the panel does not use automatic arming.
If the user has Extend Schedule authority,  2HR  4HR  6HR  8HR  
displays at disarming. If the user does not make a choice, the RE 
ARM DELAY is used to extend the schedule.
Application  example:  An  exit  door  near  the  trash  is  scheduled 
to be armed at all times.  When the custodian needs to remove 
trash, program 10 minutes for the activity.  Or, an overhead door 
only requires access when a delivery is made. Program up to 250 
minutes to allow the loading doc supervisor to load or unload a 
semi-truck.
Browser Feature
Refer to Appendix B in this guide for a diagram showing you how to 
use the Output Group browser.