User`s guide
26  XR500/XR100 User’s Guide User Menu
  XR500/XR100 User’s Guide  27User Menu 
Browser Feature
If  you  are  unsure  of  the  zone  number  or  description,  refer  to 
Appendix  B  at  the  back  of  this  guide  for  a  diagram  showing  you 
how to use the built-in Bypass Zones browser.
Zone Monitor 
Allows  the system  to  monitor  selected disarmed  zones  (doors, 
windows, or motion detectors) and  display their name at the 
keypad as they are faulted. This feature could be used to monitor 
an access door.
Zone  Monitor  works  with  any  disarmed  zone  and  also  sounds 
the  keypad  monitor  tone  when  the  zone  faults.   The  zone  name  
displays at all keypads designated for the area in your system.
You can place any combination of disarmed zones in Zone Monitor 
but  only  the  most  recent  zone  faulted  displays.    The  displayed 
zone  name  clears  automatically  after  a  short  time  or  when  the 
zone is armed.
Monitor (Chime) Shortcut Key
All Systems — Press 5 for 2 seconds when the system is disarmed. 
This initiates  the  Zone Monitor operation  for  all  Exit zones  in  an 
Area  system  or  all  zones  assigned  to  the  perimeter  in  a  Home/
Sleep/Away  or  All/Perimeter  system.    The  keypad  displays 
MONITOR ON and chimes or displays MONITOR OFF and no tone is 
sounded. 
Testing your system’s burglary protection
After using  the System  Test function, place  all zones  in Zone 
Monitor.  Starting at the front door, go around and open and then 
close  each  door  and  window.    You  should  hear  the  keypad  beep 
each time.  The keypad also displays the name of each zone as its 
device is opened. 
Once the protected doors and windows test is complete,  walk  in 
front of each motion detector. The keypad should beep to conrm 
the  zone  has tripped.   If  at  any  time  during your  weekly  testing 
a  device  does not  cause  the  keypad  to  beep, call  the  service 
department for assistance.
Using the Zone Monitor Function
1.  Access the User Menu.
2.  Press COMMAND until ZONE MONITOR? displays.
3.  Press  any  Select  key.    The  keypad  displays      ALL    NBR  or 
PERIM ALL NBR.
4.  Select  PERIM  to  place  all  disarmed  perimeter  zones  into 
Zone Monitor. 
4a. The keypad displays ALL? ADD RMV.
4b.  Select ADD to add all disarmed zones to Zone Monitor.
4c. Select RMV to remove all disarmed zones.
5.  Select ALL to place all disarmed zones into Zone Monitor.
5a. The keypad displays ALL? ADD RMV.
5b.  Select ADD to add all disarmed zones to Zone Monitor.
5c. Select RMV to remove all disarmed zones.
6.  Select  NBR  to  enter  a  specic  zone  number  for  zone 
monitor.
7.  If you select NBR, the keypad displays ZONE: - ADD RMV.
7a. Enter  any zone  number and  select  ADD to  add this 
zone.
7b.  Enter any zone number and select RMV to remove this 
zone.
8.  The  zone  number  automatically  disappears.  You  can  then 
enter a new zone number and repeat step 7a or 7b.