Arming an All/Perimeter System
1.  Enter your 4-digit user code.  The keypad displays   PERIM     
ALL.
2.  Select PERIM to arm the Perimeter area only. 
3.  Select ALL to arm both the Perimeter and Interior areas.
4.  The keypad displays zones that have been bypassed prior to 
arming and zones that are now in a faulted condition. 
5.  At this point you can force arm or bypass any faulted zones.  
A zone that is force armed is restored into the system if it 
later returns to normal.  A bypassed zone remains bypassed 
until the system is disarmed. See steps 5a through 5d.
5a. If  a  problem  exists  on  any  zones,  the  zone  name  and 
problem display followed by: OKAY BYPASS STOP.
5b.  Select OKAY to force arm the zone(s) before arming.
5c. Select BYPASS to bypass the zone(s) before arming.
5d.  Select STOP to stop the system  from  arming.    Correct 
the zone problem(s) and return to step 1.
6.  The keypad displays PERIMETER ON if only the perimeter is 
being armed and ALL SYSTEM ON if both the perimeter and 
interior are being armed.
7.  The  keypad  next  displays  EXIT:    ##  INSTNT  and  begins  to 
count  down  the  number  of  seconds  remaining  for  you  to 
exit. When the delay expires, all zones are armed.
8.  You  can  select  INSTNT  while  EXIT:    ##  INSTNT  displays  to 
immediately  arm  all  zones  and  make  them  instant.    The 
keypad  displays  INSTANT.    When  you  select  INSTANT,  any 
entry/exit  zone  that  trips  immediately  activates  an  alarm 
and the exit delay countdown immediately stops.
9.  When  the  system  is  fully  armed,  the  keypad  displays 
PERIMETER ON for perimeter arming and ALL SYSTEM  ON for 
perimeter and interior arming.
All/Perimeter System Disarming
Disarming:  While  the  system  is  armed,  you  can  only  enter  the 
premises through  an  entry/exit delay  door  without causing  an 
alarm.  After opening the door, the keypad sounds a prewarn tone 
to remind you to disarm the system.  You must disarm the system 
before the prewarn tone expires or an alarm on the door zone will 
occur.
During the prewarn tone, the keypad displays ENTER CODE:. Enter 
your user code to disarm the system.
Schedules: If you have programmed schedules for your system and 
a user code is entered outside of a schedule, the keypad displays 
INVALID  TIME.    This  lets  the  user  know  that  they  are  disarming 
outside of their authorized time. 
Alarm  Display:  After  disarming,  the  keypad displays  any  zones 
that  tripped  or  any  transmission  problems  that  occurred  during 
the armed period.  All burglary  zones are then disarmed and any 
bypassed zones are automatically reset.
Disarmed Message: The keypad displays ALL SYSTEM OFF after the 
system disarms.
Central Station Report: A  report  of  the system disarming can be 
transmitted  to  the  central  station.    This  is  optional  and  can  be 
programmed for you at any time.