Specifications

1070 072 131-102 (96.08) GB
BUEP03E Protocol 8-35
8.8.3 Error Class
The error class refers to the generation point of the fault information. The
following conventions apply:
Error class Explanation
00H Fault-free
30H System bus
31H Operating system
40H BÜP03E fault messages
FFH Fault message of the function modules
Fig. 8-18 BÜP03E — Error class
8.8.4 Error Catalogue
Fault information
PLC
response
Error class Error code Explanation
00 00 00 Fault-free job
00 30 00 Receive acknowledgement
00 30 01 Command executed fault-free
00 31 00 No fault
02 40 05 Command already active - no start
03 30 90 Field type undefined on receiving module
03 30 92 Invalid command parameter
03 30 93 Wrong address alignment
03 30 94 Address fault
03 30 D6 Module number too large
03 30 D7 Module not available
03 30 D8 Data module too small
03 31 56 Destination module unknown
03 40 01 Parameter fault in the job string
03 40 02 Data loss in the BÜP03E Receive buffer
03 40 08 FO - format fault
03 40 09 FO - no or only separator
03 40 0A FO - too many variables
05 40 03 Receive buffer empty
05 40 06 UART transmit/receive fault
09 31 50 System bus not allocated
09 31 52 Partner command buffer full
09 31 53 Command execution interval elapsed
09 40 07 Receive active - no mode change
10 31 60 Passive job terminated
10 31 61 Active job terminated
10 40 04 Abort via abort character
Fig. 8-19 BÜP03E — Fault messages