Specifications
1070 072 131-102 (96.08) GB
BUEP03E Protocol 8-19
8.7.3.5  RECEIVE MODE Command
Description: The following modes can be selected with this command:
- Start character
- End character
-  Number of BCC
- Termination character
-  Marker number for interlinking depth
The selected Receive modes are valid until they are redefined. The Re-
ceive modes can be modified within a command chain if the Receive
process (Receive command) is inactive. If an attempt is made to modify a
receive mode while Receive is active, the process is terminated and a
fault message is issued.
The receive mode values are reset during
-  Power ON and when the standby supply is defective or missing
-  loading of the protocol
and remain unchanged during a
-  R500 Reset procedure
- Stop/Run procedure
During a ZS Stop/Run procedure the R500 operating system terminates
all inactive jobs, and activates a Terminate Job sequence for active jobs.
An R500 Reset procedure is not registered by the central processing unit.
Basic adjustment of the receive mode values:
-  No start character
-  No end character
- No BCC
-  No termination character
-  Interlinking depth not returned
Syntax:
As on Page 8-15 in the Start - Syntax section.