BUEP03E Protocol8-12
8.7.2.1 Interlinking via BÜP03E START Command
The associated job parameter lists are filed contiguously one after the
other in the PLC memory (DM, DB, DF). Each job parameter list specifies
a command (==> job). The sequence of the commands in the PLC me-
mory specify the positions of the commands. Application-specific combi-
nations of the command positions can be stipulated with the Start
command.
If the Start command is now started by means of the R5REQ function
module, the command chain, indicated via identifiers, is retrieved from
BÜP03E and executed according to the stipulated sequence.
R5REQ parameter
PW1 - PW3
Command 1
Receive
Command identifier ‘ST’ Command 2
Receive mode
Identifier for the
command chain
Command 3
Reset Receive Buffer
No. of parameter list: 4 Command 4
Transmit
12
FFH 4
Start command Job parameter lists are located
directly behind each other in
the job memory (DM,DF,DB)
Fig. 8-6 BÜP03E — Interlinking command
The jobs are processed in the following sequence: 2, 1, 4, End
With this method the maximum job memory is restricted to one data mo-
dule ( = 512 bytes). A maximum of 16 commands can be defined per job
memory and, depending on the application, can be linked to each other.
This method unloads the system bus by transferring all the job parameter
lists once. A command may occur several times in the command chain.
During the active phase of Receive, the following individual commands
can be started parallel to the commenced command chain:
- Data Copy
- Transmit
- Reset Receive Buffer
- Receive Mode
- Formatted Output
Parallel operation is only possible with Receive in the command chain, not
in single command mode.