Specifications

1070 072 131-102 (96.08) GB
R5CON Confirmation Module6-2
6.2 I/O Parameters
The R5CON confirmation module has two input and three output para-
meters.
P0 P2
R5CON P3
P1 P4
6.2.1 Input Parameters
Parameter Att. Description
P0 W CXN and channel number
This parameter indicates the CXN and the number of the channel on
which the corresponding job has been processed.
Parameter Att. Description
P1 W Job number (0 to 7FFFH, FFFEH or FFFFH)
Permitted entries are:
Job numbers from 0 to 7FFFH or
the FFFFH and FFFEH wildcard characters
Using the information supplied by a job number 0 to 7FFFH, the user se-
lects precisely that job which he would like to acknowledge. A specific job
is therefore checked systematically.
The indicated job number is mirrored in the P2 output parameter.
If the FFFEH wildcard character is indicated as a job number, the R5CON
function module acknowledges all the jobs (from the interface named by
P0) which ended without fault up to this time.
If jobs also ended with faults, the R5CON also acknowledges the defecti-
ve job which has the highest job number and returns its status and error
codes in the output parameters. Any other defective jobs are not
acknowledged by this R5CON call-up.
If the job has ended, the value FFFFH is signalled back to the P2 output
parameter.
If only fault-free jobs have ended, these are all acknowledged and the
value FFFEH is signalled back to the P2 output parameter.
If the FFFFH wildcard character is indicated in the P1 parameter, the
R5CON acknowledges the job which has been processed by the R500,
although this acknowledgement has still not been retrieved. If this applies
to several jobs, the job with the highest job number is acknowledged. This
job number is then entered in the P2 output parameter. All other jobs are
not acknowledged.