Specifications
1070 072 131-102 (96.08) GB
R5REQ Function Module5-4
5.3 Explanations of Parameters in Data Range
A parameter field of 16 words must be reserved for each job in the data
field DF, data buffer DB or data module DM.
The address and offset of this data range are specified with the P0 - P2
parameters for the R5REQ module.
A bit which starts with Bit 0 (zero) is assigned to each parameter field in
the job bit array JBA and in the result bit array RBA.
Example of associated data area when the P2 parameter (offset) has the
value 0:
Job bit of the JBA Associated data area Byte addresses
0 DW0 - DW15 0 - 31
1 DW16 - DW31 32 - 63
2 DW32 - DW47 64 - 95
3 DW48 - DW63 96 - 127
4 DW64 - DW79 128 - 159
5 DW80 - DW95 160 - 191
6 DW96 - DW111 192 - 223
7 DW112 - DW127 224 - 255
8 DW128 - DW143 256 - 287
9 DW144 - DW159 288 - 319
10 DW160 - DW175 320 - 351
11 DW176 - DW191 352 - 383
12 DW192 - DW207 384 - 415
13 DW208 - DW223 416 - 447
14 DW224 - DW239 448 - 479
15 DW240 - DW255 480 - 511
Fig. 5-2 R5REQ — List of parameters
The max. 16 job parameters are divided into two groups.
1. Protocol-independent parameters:
Their content is always the same, irrespective of the protocol and/or ser-
vice which is actuated by the subsequent parameters.
2. Protocol-dependent parameters:
These parameters differ for all protocols and/or services.