Specifications

1070 072 131-102 (96.08) GB
R5INIT Initialisation Function Module 4-1
4 R5INIT Initialisation Function Module
4.1 Characteristic Data
Characteristic data R5INIT
Module name R5INIT
Block length 871 words
Call-up length 7 words
Number of parameters 6
Used markers M230 to M254
Fig. 4-1 R5INIT — Characteristic data
The R5INIT initialisation function module creates various tables in the
ZS and on the computer interface module and fills them with information
which is re-accessed when these modules are communicating.
When the controller has been switched on, the program cycle should and
may only run once on this module before communication can occur via
the computer interface. The module is therefore usually called up in the
OM5 and/or OM7 start-up organisation module.
NOTE –
If the R500 is operated only as a server, the R5INIT module is NOT
required.