Specifications
1070 072 131-102 (96.08) GB
Hardware Description 2-3
2.3.1 Status Display
There is a status display for each of the two channels on the R500 Com-
puter interface module.
The H31 7-segment display is linked to Channel 1.
The H32 7-segment display is linked to Channel 0.
2.3.2 Interface Connectors
The X31 and X32 interface connectors comprise the V.24/20 mA interfa-
ces (please refer to Page 2-5). These interfaces are used for point-to-
point connection to an external device.
2.3.3 Reset Button
The R500 operating software is re-initialised by pressing the Reset button.
• All active jobs are cancelled irrespective of status.
• All jobs are deleted from the job queue.
• STOP and CLAB module requests are cancelled.
2.3.4 Version ID
The version identification is used to identify the individual release ver-
sions. Each version modification is identified by a white dot.
2.3.5 Labelling Field
The labelling field enables the user to mark the module exterior with a sy-
stem-specific designation. This could be the block address of the module,
for example.