Specifications
1070 072 131-102 (96.08) GB
BUEP64 Protocol 9-33
9.12.3 SEND Job (CL500 -> CL500)
Four (4) words, beginning with the byte address 12H (word number 9H),
are written, without coordination, from the DM5 data module in the ZS500
with block address 10H to the DM9 data module in the ZS500 with mo-
dule number 2 from byte address 24H (word number 12H).
The transfer is processed by Channel 1 of the R500 with the number 2
(CXN2 see R5INIT parameterisation).
The job receives job number 4.
The job is parameterised as follows:
Param. word Contents Explanation
PW1 --- No entry
PW2 0201H CXN2, Channel 1
PW3 4H Job number 4
PW4 4101H Output job (SEND) / word
PW5 4444H RST code: DM PST code:
DM
PW6 5H RST address: DM number 5
PW7 10H RST address: Block addr. ZS2 = 10H
PW8 9H RST address: Data word no. 9
PW9 9H PST address: DM no. 9
PW10 --- No entry
PW11 12H PST address: Data-word no. 18
PW12 9H Volume of data: 9 words
PW13 FF2FH Without coordination, module number 2
PW14 --- No entry
PW15 --- No entry
PW16 --- No entry
Fig. 9-18 BÜP64 — Example of SEND parameters (CL500 -> CL500)