Specifications
1070 072 131-102 (96.08) GB
BUEP64 Protocol9-18
9.10.2 PLC Response
The PLC response is intended to provide the user with advice and help on
the faults within the fault information.
The following conventions apply:
PLC response Explanation
00H No response, job fault-free
01H Repeat FM job
02H Program fault, change PLC program
03H Change protocol parameter
04H Rerun the program cycle on the R5INIT
05H Rerun the program cycle on the R5REQ
06H Rerun the program cycle on the R5CON
07H Reload the protocol
10H Active job terminated by the user
20H Job fault-free, however with reduced data length
Fig. 9-3 BÜP64 — PLC response