Instruction manual
- 48 - 
The general operations are as below: 
  ▲▼◄► 
Press these buttons to select the items. 
  MODE => Format/Clear 
Press this button to format/clear the HDDs as described in Section 6.6.1
. 
  ESC 
Press this button to escape from this screen, and return to Setup Menu display. If 
the Save dialog is shown, press ENTER to exit and save, ESC to exit without 
saving. 
Following is a brief description for each item and its specific operations: 
  Size (GB) – the total HDD storage in GB (Giga-Byte) for Alarm Record and 
Normal Record respectively.    This item is just for information.    Please refer to 
Section 6.6.1
 for more detailed information and setup of each individual HDD. 
  Auto Overwrite – automatic overwrite of the recorded video/audio from HDD#1 
when the Alarm/Normal Record disk drive capacity reaches the end of the last 
HDD.    If Auto Overwrite is disabled and the Alarm/Normal Record disk drive 
capacity reaches the end, the system will not overwrite the recorded video/audio, 
and hence not record Alarm/Normal video/audio, until the user presses the Alarm 
Reset button. Press ENTER or +/- to check/uncheck this item.    The default 
setting is “” - checked. 
  HDD Full Action – actions when Alarm/Normal Record disk drive capacity 
reaches the end of the last HDD.   Press ENTER or +/- to check/uncheck this 
item. The default setting is “” - checked. 
  Duration – response duration to define at most how long (in seconds) the Alarm 
Out relay and the Buzzer will keep being triggered after the corresponding 
partition, Alarm Record or Normal Record, is full. Press +/- buttons to adjust the 
value (3 seconds - 60 minutes, discrete, ‘-‘ for ‘Forever’). 
  Alarm Out – to define which Alarm Output will be triggered when the 
corresponding partition, Alarm Record or Normal Record, is full. Press +/- 
buttons to select none (N/A) or one of the Alarm Outputs (1-4). 
  Buzzer – to activate the internal Buzzer or not when the corresponding partition, 
Alarm Record or Normal Record, is full.    Press ENTER or +/- to check/uncheck 
this item. The default setting is “” - checked. 
  Log – to log to event logs or not.   Press ENTER or +/- to check/uncheck this 
item. The default setting is “” - checked. 
SCW-7709 & SCW-7716 Users Manual
SCW-7709 & SCW-7716 Users Manual