Installation Instructions
13
500
-1
0
42
0,
R
e
v
G
Figure 19. Magnalock and Strike Plate Alignment
5. ENSURE the Magnalock and strike plate are in proper alignment.
WARNING: A shock hazard may occur if the Magnalock is operated from a
DC power supply that is connected to earth ground or not
isolated.
CAUTION: The Magnalock must be operated from DC powe
r
supply o
f
appropriate capacity and voltage. The DC output of the
power supply must not be
connected to earth ground but
must be isolated, or possible damage to the
product could
result.
NOTE: In order to confirm that the DC outputs of a power supply are
isolated, it can be checked with an ohmmeter between earth
ground
and +V, and then between earth and 0V (negative). There
should not be continuity.
6. CONNECT the wiring per Figure 20, “Typical Magnalock Wiring,” Figure 21,
“Connections for BondSTAT ‘B’ Version,” Figure 22, “Connections for DPS
‘D’ Version,” and Figure 23, “Connections for ‘BD’ Version.”
Figure 20. Typical Magnalock Wiring