Installation Instructions

Mounting an
Enclosure to a Wall
Use the following procedure when
mounting a wall-mount enclosure.
1 (Optional) Remove the enclosure’s cover.
2 Locate the top keyhole mounting holes
in the back of the enclosure.
3 Mark and pre-drill the locations for the
keyholes in the mounting surface.
4 Partially install two fasteners appropriate for
the surface on which the enclosure is being
installed. Leave the heads of the fasteners
approximately 1/4" out from the surface.
Minimum fastener size should be #10 or larger.
5 Hang the enclosure on the two fasteners and mark
the locations of the remaining mounting holes.
6 Remove the enclosure and pre-drill the
locations for the remaining mounting holes.
7 Re-hang the enclosure on the top
mounting fasteners, start the remaining
fasteners and tighten all fasteners.
8 Reinstall the enclosure’s cover, if removed in step 1.
It is the installers responsibility to determine the
appropriate fastening system for use with the
surface the enclosure is being mounted to.
For UL1076 applications, after installation is
complete, the installer must install the two
supplied 1" long screws to the edge of the
enclosure’s cover for additional security.
Mounting Power Boards
to the Enclosure
Mounting a Securitron Intelligent Power Board to an
enclosure is via the four snap-in standoffs supplied.
1 Locate the appropriate mounting holes in the
enclosure and snap the standoffs into the holes.
2 Align the board mounting holes with the standoffs
(be sure the PC board is properly oriented)
and snap the board onto the standoffs.
Securitron AQL6, 102, 104
Securitron AQL4
5