3.6.1 Entering Diagnostics Mode
Usage: Toggle Unit Into and Out of Diagnostics Mode From Normal Run Mode
1) Press and hold Call Button for approx. 12 seconds
2) Unit will generate a “mystery” tone to indicate the unit is entering or leaving Diagnostics Mode
3) Alert LED will begin to flash a pattern when entering Diagnostics Mode
NOTES:
1) Once in Diagnostics Mode, Location updates can be generated to the server on demand by pressing the
Call Button for approximately 1 second (Unit will generate a short “beep” tone).
Diagnostics Mode Alert LED Pattern Description:
Repeating Diagnostics Mode Alert LED Pattern Description:
1) Long LED pulse: New Pattern Sequence Beginning
2) Short pause
3) One, two, or three short LED pulses: GPS Status
1. One pulses: GPS Module Not Running (Sleeping or Error)
2. Two pulses: Invalid GPS Fix
3. Three pulses: Valid GPS Fix
4) Short pause
5) One to thirteen short LED pulses: GPS Satellites In View
1. One pulse: No Satellites In View
2. Greater than one pulse: Number of pulses minus one number of satellites in view
6) Short pause
7) One, two, or three short LED pulses: GSM and GPRS Status
1. One pulse: No GSM or GPRS registration
2. Two pulses: GSM registered
3. Three pulses: GSM and GPRS registered
8) Short pause
9) Pattern repeats from Step #1 again
The diagnostics pattern is interpreted by counting the number of LED pulses in each set.