Instruction Manual

6
Installation Instructions
Installing the ASR-ZW Receiver
The ASR-ZW receiver should be located as
near as is practical to the boiler or zone valve to
be controlled, as well as a convenient mains
electricity supply. To remove the wall plate from
the ASR-ZW, undo the two retaining screws
located on the underside, the wall plate should
now be easily removed. Once the wall plate
has been removed from the packaging please
ensure the ASR-ZW is re-sealed to prevent
damage from dust, debris etc.
The wall plate may be fitted directly on to a single gang flush wiring box
complying with BS4662, using two M3.5 screws. The receiver is suitable for
mounting on a flat surface only; it is not suitable for mounting on an
unearthed metal surface.
Wall Box Mounting
Offer the plate to the wall in the position where the ASR-ZW is to be
mounted and mark the fixing positions through the slots in the wall plate.
Drill and plug the wall, then secure the plate into position. The slots in the
wall plate will compensate for any misalignment of the fixings.
The wall plate should be fitted with the
retaining screws located at the bottom and in a
position which allows a total clearance of at least 50mm around the ASR-ZW
receiver.
Direct Wall Mounting