User's Manual

For Flood Only Operation
The sensor is designed to automatically detect the ambient temperature of the
area where it is located. For flood only applications, the Digital Life Controller
will require programming to ignore the temperature reports.
The flood probe is supplied with a four-foot wire lead. Connect the flood probe
wires to the screw terminals located on the sensor circuit board. Observe
polarity, Black wire connects to the terminal next to the tamper switch.
Locating the Flood Probe
Find a low spot on the floor of the area to be protected. Choose a location
where the probe will not be disturbed by foot traffic and cleaning equipment.
.....
Mounting the Flood Probe
....
Mount the probe with the screws provided. The best installation is where the
plastic center foot is touching the floor which sets the correct probe height.
Enrolling the Transmitter
WHITE WIRE
BLACK WIRE