System information

Supplemental Information
108
ProSAFE Single Band 802.11n Wireless Access Point WN203
Factory Default Settings
You can use the Reset to Factory Defaults button located on the bottom panel of the wireless
access point to reset all settings to their factory default. This is called a hard reset.
To perform a hard reset, use a sharp object to press and hold the Reset to Factory Defaults
button for approximately 10 seconds. This returns the wireless access point to the factory
configuration settings that are shown in the following table.
Note: Pressing the Reset to Factory Defaults button for a few seconds
simply causes the wireless access point to reboot.
Status LEDs Power LED
Test LED
LAN LED
WLAN LED
Electrical and physical specifications
Power adapter 12VDC, 1A; plug is localized to country of sale
Power consumption 4.0W
Physical specifications Dimensions (h x w x d): 35 x 133 x 173 mm (1.4 x 5.3 x 6.8 in.)
Weight: 240 g (0.5 lb)
Environmental
specifications
Operating temperature: 0 to 45°C (32 to 113°F)
Operating humidity: 10–90%, noncondensing
Storage temperature: –20 to 70°C (–4 to 158°F)
Storage humidity: 5–95%, noncondensing
MTBF At 25°C > 375,000 hours
At 50°C > 125,000 hours
Electromagnetic
compliance
SRRC
Table 5. Technical specifications (continued)
Feature Description