Use and Care Guide
2
598-1159-07
For eave mount only:
1. Rotate the sensor head towards the clamp screw
joint.
2. Then rotate the sensor head clockwise 180° so the
controls face down.
Control Switch
Joint Clamp
Move ON-TIME Switch
to 1, 5, or 10 minutes
Mode Switching Summary
Flip light switch
off for one second
then back on*
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
CAUTION: The sensor must be mounted
below the lamp housing for wall installations.
INSTALLATION
For easy installation, select an existing light operated
by a wall switch for replacement. IMPORTANT: Do NOT
use with dimmers or timers.
For best performance, mount the xture about 8 feet
(2.4 m) above the ground. NOTE: If xture is mounted
higher than 8 feet (2.4 m), aiming the sensor down will
reduce coverage distance.
CAUTION: To Avoid Fire Or Burn Hazards:
• Allow xture to cool before touching. The bulb and
the xture operate at high temperatures.
• Keep xture at least 2" (51 mm) from combustible ma-
terials. Do not aim at objects closer than 3 feet (1 m).
• Use only T3, 150W (maximum) tungsten halogen
120 VAC lamps.
NOTE: Light xture and sensor should be mounted as
shown above when installed (depending upon type of
installation).
CAUTION: Keep the sensor at least 1" (25 mm)
away from the bulbs.
Before installing the light fixture under an eave, the
sensor head must be rotated as shown in the next
two steps for proper operation and to avoid the risk of
electrical shock.
Wall Mount Eave Mount