Installation Guide

6
200478-03
DUAL BRITE
®
ON-TIME
TEST 1 5 10 MIN
OFF 3 6
DUSK
TO DAWN
DUAL BRITE
®
ON-TIME
TEST 1 5 10 MIN
OFF 3 6
DUSK
TO DAWN
MOUNTING THE LIGHT FIXTURE
1. Make sure wire connectors and wires are inside the
junction box.
2. Slide the xture base onto the mounting screws and
tighten the decorative nuts snugly against the base.
3. Install four candelabra base light bulbs (25 Watts
maximum each, tungsten incandescent).
4. Refer to
Testing and Adjustments
section before installing
cover.
TESTING AND ADJUSTMENTS
Initial Setup
e TEST mode overrides the photocell (daylight shuto
feature) and allows the light xture to be tested day or night
when the ON-TIME switch is in the TEST position. e
light will stay on for 5 seconds after all motion has stopped.
Maximum Range Maximum Coverage
Angle* (Top View)
Sensor Controls
1. Turn the DualBrite control to OFF.
2. Set the ON-TIME control to TEST.
3. Set SENSITIVITY control to MIN position.
4. Turn on the circuit breaker or fuse and the light switch.
5. Allow the sensor to completely warm up (90 seconds)
before beginning the setup process.
6. Perform a walk test. Walk in an arc across the front of
the sensor.
Mounting Screw
Junction Box
25 Watt Candelabra
Base Bulb
DualBrite
®
ON-TIME
DUSK
OFF
3
HR 6HR TO DAWN
TEST 1 5 10 MIN
Sensor
Lens
SENSITIVITY
+
+
SENSITIVITY
30 Feet (9.1 m) in
all Directions
8 ft. (2.4 m)
360°
* Without lens shield installed.
Decorative
Nut