Use and Care Guide
7
200478-02
SPECIFICATIONS
Range ........................... Upto30ft.(9.1m)[varies
with surrounding tem-
perature].
SensingAngle .............. 360°
ElectricalLoad .............. Upto100WattMaximum
Tungsten Incandescent
(Upto25WattMaximum
each lamp holder).
Bulb Type ...................... Candelabra Base, Type
“B”,25WattMaximum
SYMPTOM
Light stays on
continuously.
Light flashes on
and off.
Light does not
stay on in Man-
ual mode.
POSSIBLE CAUSE
1. There is a heat source like an
air vent, dryer vent, or brightly-
painted,heat-reectivesurfacein
the coverage area. (Install shield
on sensor in the direction of heat
source.)
2. LightcontrolisinManualMode.
(Switch to Auto.)
3. Light control is in DualBrite
®
mode.
4. Sensitivityissettoohigh.(Reduce
sensitivity.)
1. Sensor is in the Test mode. (While
in TEST mode, light only stays on
for 5 seconds.)
1. Nearbylarge,light-coloredobjects
reecting light may trigger the
shut-off feature. Do not point other
lights at the sensor.
POSSIBLE CAUSE
1. Lightswitchisturnedoff.
2. Bulbsarelooseorburnedout.
3. Fuseisblownorcircuitbreaker
is turned off.
4. Daylightturn-offisineffect(re-
check after dark).
5. Incorrectcircuitwiring,ifthisis
anewinstallation.
1. Sensor may be installed in a
relatively dark location.
2. Sensor is in Test. (Set control
switch to an ON-TIME position.)
1. Sensor may be sensing small
animals or automobile traffic.
(Reduce sensitivity.)
SYMPTOM
Light will not
come on.
Light comes on
in daylight.
Light comes on
for no apparent
reason.
TROUBLESHOOTING GUIDE
Sensor Capacity ........... Up to 200Watt (1.7 A.)
Maximum Tungsten In-
candescent
PowerRequirements ....120VAC,60Hz
Operating Modes .......... TEST, AUTO/ACCENT,
andMANUALMODE
ON-Timer ...................... 1, 5, 10 minutes
DualBrite
®
Timer .......... Off, 3, 6 Hrs, Dusk-to-
Dawn