Use and Care Guide

7
200478-02
SPECIFICATIONS
Range ........................... Upto30ft.(9.1m)[varies
with surrounding tem-
perature].
SensingAngle .............. 360°
ElectricalLoad .............. Upto100WattMaximum
Tungsten Incandescent
(Upto25WattMaximum
each lamp holder).
Bulb Type ...................... Candelabra Base, Type
“B”,25WattMaximum
SYMPTOM
Light stays on
continuously.
Light flashes on
and off.
Light does not
stay on in Man-
ual mode.
POSSIBLE CAUSE
1. There is a heat source like an
air vent, dryer vent, or brightly-
painted,heat-reectivesurfacein
the coverage area. (Install shield
on sensor in the direction of heat
source.)
2. LightcontrolisinManualMode.
(Switch to Auto.)
3. Light control is in DualBrite
®
mode.
4. Sensitivityissettoohigh.(Reduce
sensitivity.)
1. Sensor is in the Test mode. (While
in TEST mode, light only stays on
for 5 seconds.)
1. Nearbylarge,light-coloredobjects
reecting light may trigger the
shut-off feature. Do not point other
lights at the sensor.
POSSIBLE CAUSE
1. Lightswitchisturnedoff.
2. Bulbsarelooseorburnedout.
3. Fuseisblownorcircuitbreaker
is turned off.
4. Daylightturn-offisineffect(re-
check after dark).
5. Incorrectcircuitwiring,ifthisis
anewinstallation.
1. Sensor may be installed in a
relatively dark location.
2. Sensor is in Test. (Set control
switch to an ON-TIME position.)
1. Sensor may be sensing small
animals or automobile traffic.
(Reduce sensitivity.)
SYMPTOM
Light will not
come on.
Light comes on
in daylight.
Light comes on
for no apparent
reason.
TROUBLESHOOTING GUIDE
Sensor Capacity ........... Up to 200Watt (1.7 A.)
Maximum Tungsten In-
candescent
PowerRequirements ....120VAC,60Hz
Operating Modes .......... TEST, AUTO/ACCENT,
andMANUALMODE
ON-Timer ...................... 1, 5, 10 minutes
DualBrite
®
Timer .......... Off, 3, 6 Hrs, Dusk-to-
Dawn