Installation Guide

8
207738-01
TROUBLESHOOTING GUIDE
SPECIFICATIONS
Range ..........................................Up to 30 ft. (9.1 m) [varies with surrounding temperature]
Sensing Angle..............................Up to 180°
Electrical Load ............................Up to 60 Watt Maximum Incandescent or UL Listed Self-Ballasted LED Lamp.
Bulb Type ....................................Medium Base, Type “A-15”, 60 Watt Maximum
Sensor Capacity ...........................
Up to 360 Watt (3.0 A) Maximum Tungsten or UL Listed Self-Ballasted LED Lamp.
Power Requirements ....................120 VAC, 60 Hz
Operating Modes ........................TEST, AUTO, and MANUAL MODE
ON-Timer ...................................1, 5, 10 minutes
DB® Timer ....................O, 3, 6 hours, dusk-to dawn
Test Timer ...................................5 Seconds
Manual Mode Timer ................... Dusk-to-Dawn
SYMPTOM POSSIBLE CAUSE SOLUTION
Lights will not
come on.
1. Light switch is turned o.
2. Light bulb is loose or burned out.
3. Fuse is blown or circuit breaker is turned o.
4. Daylight turn-o is in eect.
5. Sensor not detecting movement.
6. Incorrect circuit wiring, if this is a new installation.
1. Turn light switch on.
2. Check bulb and replace if burned out.
3. Replace fuse or turn circuit breaker on.
4. Recheck after dark.
5. Adjust sensitivity control.
6. Verify wiring is correct.
Lights come on in
daylight.
1. Light control may be installed in a relatively dark location.
2. Light control is in TEST.
1. e xture is operating normally under these conditions.
2. Set control switch to 1, 5, or 10 minutes.
Lights come on for
no apparent reason.
1. Light control may be sensing small animals or automobile
trac.
2. Sensitivity is set too high.
1. Reduce sensitivity.
2. Reduce sensitivity.
Lights stay on
continuously.
1. e sensor may be picking up a heat source like an air vent,
dryer vent, or brightly painted, heat-reective surface.
2. Light control is in Manual Mode.
3. Light control is in DB® mode.
4. Sensitivity is set too high.
1. Reduce sensitivity.
2. Switch to Auto.
3. Slide DB® switch to OFF position.
4. Reduce sensitivity.
Lights ash on
and o.
1. Light control is in the TEST mode and warming up.
2. Heat being reected from other objects may be aecting the
sensor.
1. Flashing is normal under these conditions.
2. Reduce sensitivity.
Seasonal Temperature Changes – e closer the surrounding temperature is to a person’s body heat, the less sensitive the sensor will appear. e greater
the temperature dierence, the more sensitive the sensor will appear. e SENS control might need to be readjusted toward MIN or MAX as the outside
temperature changes for the dierent seasons. is is a normal part of the light sensor’s operation.