Use and Care Guide
6
200477-02
The detector is less sensitive to motion di-
rectly towards it and more sensitive to across 
motion.
Sensor
Motion
Least Sensitive  Most Sensitive
3.  Walk through the coverage area noting 
where you are when the lights turn on.
4. If you need to change the sensitivity, 
temporarily remove the fixture and make 
the adjustment. Too much sensitivity may 
increase false triggering.
5.  Set the amount of TIME you want the light 
to stay on after motion is detected. (1, 5, 
or 10 minutes).
6.  Set the amount of time after dusk you want 
the lights on accent level.
TEST 1 5 10 MIN
ON-TIME
OFF 3 6 DUSK TO
  HOUR DAWN
30 ft. 
(9.1 m)
180°
Motion
2.  Switch the on-time to TEST position and 
DualBrite
®
 switch to the OFF position.
6 ft. 
(1.8 m)
TESTING
1. Turn on the circuit breaker and light 
switch.
  Maximum Range  Maximum
    Coverage Angle
Avoid aiming the control at:
•Pools of water or objects that change 
temperature rapidly, such as heating vents 
and air conditioners. These heat sources 
could cause false triggering.
•Areaswhere pets or traffic may trigger 
the control.
•Nearby large, light-colored objects 
reectingdaylightmaytriggertheshut-off
feature. Do not point other lights at the 
sensor.
Note:  Sensor has a 1 
1
/
2
 minute warm up pe-
riod before it will detect motion. When 
first turned on wait 1 
1
/
2
 minutes.