Use and Care Guide

6
200476-02
TESTING
1. Turn on the circuit breaker and light
switch.
30 ft.
(9.1m)
Maximum Range Maximum
Coverage Angle
Avoid aiming the control at:
•Pools of water or objects that change
temperature rapidly, such as heating vents
and air conditioners. These heat sources
could cause false triggering.
•Areaswherepets or traffic may trigger
the control.
•Nearby large, light-colored objectsreect-
ing daylight may trigger the shut-off feature.
Do not point other lights at the sensor.
Note: Sensor has a 1
1
/
2
minute warm up pe-
riod before it will detect motion. When
first turned on wait 1
1
/
2
minutes.
150°
TEST 1 5 10 MIN
ON-TIME
OFF 3 6 DUSK TO
HOUR DAWN
2. Switch the on-time to TEST position and
DualBrite
®
switch to the OFF position.
6 ft.
(1.8)
4. If you need to change the sensitivity,
temporarily remove the fixture and make
the adjustment. Too much sensitivity may
increase false triggering.
5. Set the amount of TIME you want the
light to stay on after motion is detected.
(1, 5, or 10 minutes).
6. Set the amount of time after dusk you
want the lights on accent level.
3. Walk through the coverage area noting
where you are when the lights turn on.
Move the sensor head left or right to
change the coverage area. Note: Grasp
the sensor only as shown and turn the
entire sensor. Any other method may
damage the sensor. Do not force it past
the stops.
Least Sensitive Most Sensitive
The detector is less sensitive to motion di-
rectly towards it and more sensitive to across
motion.
Sensor
MotionMotion
Rotating Sensor Head to Change Coverage
Area
1
5
0
°
1
5
0
°