Hardware manual

80-001113 SysLINK Administrator’s Guide Page 75
Supported Commands
Command
Function
Result
/
Repeat last command
Varies
Note: command executes upon "/"
character. CR not needed.
<blank>
Attention
OK(0)
A
Answer
OK(0), NO CARRIER(3)
D
Dial
CONNECT(1), NO CARRIER(3)
If suffixed with ";" character, will return to
command mode upon connection.
En
Echo Mode
0=Turn command echo off
1=Turn command echo on (default)
OK(0)
Hn
Hangup
Terminate connection.
Optional argument has no function
OK(0)
In
Information
0=Serial Port Speed
3= Model and Version
33600 (Note: Actual value equals current
port speed)
O
Return to data mode from command
mode
Qn
Result Codes
0=Enable result codes (default)
1=Supress result codes
OK(0)
<blank>
Sn=mm
Sn?
Set register to specified value (see
below)
Return current value formatted as 3
digit decimal
OK(0)
Vn
Result Code Format
0=Numerical result codes
1=Verbose result codes (default)
0
OK
Xn
Result Code Format
0="CONNECT" upon entering
online data state
1-4="CONNECT <text>" upon
entering online data state
OK(0)
Zn
Load factory default settings and
drop current connection. This
command also restores the flash
configuration for the port back to
factory default.
OK(0)