Hardware manual
80-001113 SysLINK Administrator’s Guide Page 59
System Log
By default, the gateway stores informational and error messages in the system log. You can
also configure the gateway to record debug trace data in this system log buffer (see the
section entitled Log/Debug Settings). To display the system log and trace information in
your browser window, select the System Log link in the menu:
This will open a connection to the gateway that will display the current contents of the
system log buffer. As long as you keep this window open in your browser, new messages
added to the buffer will automatically be sent to your web browser.
Log entries begin with a timestamp. The first item “(0)” is the number of days since the unit
was booted. The next 12 digits are the time in UTC time including microseconds.
Click the “save” link next to System Log to save the log as an HTML file. Click the “clear”
link next to System Log to clear the log.
You can also view and save the system log using a telnet client. To do this, connect to the IP
address of your gateway on TCP port 9096. Data in the trace buffer will be automatically
formatted and displayed in your telnet window. For example:
telnet 192.168.1.1 9096