4.3 Enroll Neew User 4.4 Delete One O User 4.5 Delete All A Users 4.6 Delete Phone P ProLogicc B22 Operation Instructtions Docume ent No: EC‐17 701A‐B22‐19 90502 Version No: V1.0 hone Managgement 5.0 Smartph 5.1 Pair Pho one 5.2 Delete Phone P on 6.0 System Identificatio I 6.1 System Info 7.0 Lock Setttings 7.1 Factory Reset (Firmw ware) 7.2 Show Au udit Trail 7.3 Enable/D Disable Vibraation Sensorr 7.4 Set Vibraation Sensitivity 7.5 Set Batteery Efficiency 8.0 Data Maanagement 8.1 Encryptiion Key Set 1.
ProLogicc B22 Operation Instrructions 1.0 System Installation 1.1 Systeem Components The systtem consists of (1) EntryP Pad – Part # EC‐1701A‐B2 22 plus (1) Lo ock body as follows: SwingBolt – Part # EL‐06 601 SwingBolt w with Status– Part P # EL‐060 01‐S DeadBolt – Part P # EL‐070 01 SpringBolt – Part #EL‐08 801 1.2 Pairiing the EntryyPad and thee Lock SecuRam m safe lock syystems can operate o in tw wo different modes depeending upon the type of EntryPad being ussed with the lock body.
ProLogicc B22 Operation Instrructions 00) is 111111 1 Supeer Code (ID0 Man nager Code (ID01) is 1234 456 *Note: In m many cases, the Super Code (ID00) is changed c from m default an nd maintaineed by the safe manufaacturer as a reset r code fo or your securrity. If you haave difficultyy resetting th he lock, pleasse call SecuR Ram Tech Sup pport at (805 5) 988‐8088 or email techsupport@securaamsys.com. 1.
ProLogicc B22 Operation Instrructions 1.5 Testting the Lockk Operation The ProLLogic B22 comes with tw wo factory deefault codes: ode (ID00) iss 111111 • Super Co • Manageer Code (ID01 1) is 123456 Enter on ne of the valiid codes to verify v the com mmunication n between th he lock and EEntryPad. Th he lock will open. 2.0 Lockk Operation Upon initial power up, u the LCD screen s starts a communiccations test as a shown below: Model Number Software Veersion Number d No. of Userss/ No.
ProLogicc B22 Operation Instrructions w the B22 you y have thee opportunitty to mask yo our code, in case someo one is watchiing you Note: with enter yo our code. On n the EntryPa ad you can enter e up to 9 digits – you ur 6 digit cod de plus up to o3 addition nal digits to m mask your code.
ProLogicc B22 Operation Instrructions mended that both these default codees are change ed before the lock system m is put into It is strongly recomm service. nge Code 4.1 Chan The B22 2 has 2 codess by default: Supeer Code: 1 1 1 1 1 1 Man nager Code: 1 2 3 4 5 6 Note: Th he default co odes must bee changed beefore usage; otherwise you cannot ad dd new userrs or pair the lock to the t APP.
ProLogicc B22 Operation Instrructions M Codees have full access a to thee programming menu. Th he User Codee only has acccess to the Note: Manager change code c menu o option, and cannot c modify any lock settings. s Step 1: Presss the Menu//OK button. p the Meenu/OK buttton Step 2: At “My Menu”, press Step 3: The display will prompt you to enter a co ode, enter a valid Super o or Manager Code, and press Menu//OK. Step 4: Afteer logging in, the screen will w show “Users”. Presss Menu/OK.
ProLogicc B22 Operation Instrructions oll New Userr 4.3 Enro After Maanager 2 Useer has been added, a you can c add a User. Step1: Presss the Menu//OK button. p the Meenu/OK buttton Step 2: At “My Menu”, press Step 3: The display will prompt you to enter a co ode, enter a valid Super o or Manager Code, and press Menu//OK. Step 4: Afteer logging in, the screen will w show “Users”. Presss Menu/OK. Step 5: Next the screen will show “EEnroll New User”.
ProLogicc B22 Operation Instrructions p the Meenu/OK buttton Step 2: At “My Menu”, press ode, enter a valid Super o or Manager Code, and Step 3: The display will prompt you to enter a co press Menu//OK. ow “Users”. Step 4: Afteer entering a valid Super or Manager code, the sccreen will sho Presss Menu/OK..
ProLogicc B22 Operation Instrructions ode, enter a valid Super o or Manager Code, and Step 3: The display will prompt you to enter a co press Menu//OK. ow “Users”. Step 4: Afteer entering a valid Super or Manager code, the sccreen will sho Presss Menu/OK.. Step 4: Scro oll “▼”or “▲” to th he menu seleection “Delete All Users”” and Press Menu/OK M Step 5: Presss the "Menu u/OK" to con nfirm Step1: Presss the Menu//OK button Now all userrs are deleteed. 5.
ProLogicc B22 Operation Instrructions Step 4: Afteer entering a valid Super or Manager code, the sccreen will sho ow “Users”. Step 5: Scroll “▼”or “▲” to th he menu seleection “Pair Phone” P and P Press Menu//OK Follow the steps s on the APP to comp plete the pairing option. 5.2 Deleete Phone This featture is used tto remove any mobile deevice conneccted to the system.
ProLogicc B22 Operation Instrructions Step 7: Presss the Menu//OK button Note: If this operatio on is perform med, the smaartphone APP will not bee able to open the lock. Iff the on such as op pening the lo ock through the t APP is reequired, it neeeds to be paaired again. operatio 6.0 System Info ‐ System Identiffication 6.
ProLogicc B22 Operation Instrructions ode, enter a valid Super o or Manager Code, and Step 3: The display will prompt you to enter a co press Menu//OK. Step 4: Afteer entering a valid Super or Manager code, scroll “▼”or “ “▲”to the menu selection “Lo ock Settings”” and Press Menu/OK M s will now n show “Faactory Resett” press Men nu/OK Step 5: The screen Step 6: Presss Menu/OK to t confirm Step 7: The screen s will prompt p the fo ollowing and d complete the factory reeset. 7.
ProLogicc B22 Operation Instrructions e menu selecction “Show Audit Trail” Step 5: Scroll “▼”or “▲”to the a the screeen will show w the most reecent event Step 6: Presss menu/OK and Step 7: The records are viewed v by "▼ ▼" or "▲”. Note e: You can viiew the histo ory log, up to o 400, and ovverwrite the oldest recorrd after the loop. ble/Disable Vibration Seensor 7.3 Enab b vibraation sensor.
ProLogicc B22 Operation Instrructions Step 6: Presss Menu/OK to t select disaable alarm. Screen S will prompt: If the screen sho ows “Disablee Vibration”: The Vibratio on Alert is en nabled. When n vibration iss sensed, the display will sshow Vibration Alert and d the buzzer w will sound. A notification will be sen nt to the paired smartpho one app. If the screen sho ows “Enable Vibration”: The T Vibration Alert is disabled: no aleert is displayyed.
ProLogicc B22 Operation Instrructions e select the level of senssitivity and press Menu/O OK. Step 6: Scroll “▼”or “▲”to the B Efficciency 7.5 Set Battery There arre two battery efficiencyy levels HI and LOW. Wheen battery efficiency is set to HI, the system will conservee power con nsumption an nd the batterry will last lo onger. This however h redu uces the com mmunication n range to o the Smart Hub.
ProLogicc B22 Operation Instrructions hat is transm mitted betweeen the EntryyPad and lock is encrypte ed, such as As a security measurre, all data th des, etc. User cod 8.1 Encrryption Key SSet The ProLLogic B22 sends and receeives data to o the lock in an a encrypted d form. This is a securityy measure to o ensure that t all data is protected. The Encryp ption Key is sset during the manufactu uring processs with a default encryption e kkey value.
ProLogicc B22 Operation Instrructions ntry of the reecovery codee, the LCD screen displayys an alpha‐numeric codee. This code cannot be Upon en used to open the saffe lock system or to chan nge the codee to factory default. d The alpha numeric code Ram’s Authorrization Codee Generator Software. must bee deciphered using SecuR ha‐numeric code c is enterred into the software s toggether with the t encryptio on code.
ProLogicc B22 Operation Instrructions C Step 9: Repeeat the 6 digit Recovery Code. The new Reccovery Code has now been set. DO N NOT lose thiss code. With hout this cod de your system cann not be recoveered. After recovery, r you can recoveer without ussing OTC for 20 minutes. over System 9.2 Reco In the evvent that you u need to recover the system during its use, the following f pro ocedure is to o be followed d.
ProLogicc B22 Operation Instrructions Step 9: Systeem will be reestored The Super Code will now w be reset to 111111. The Manageer Code will now n be resett to 123456. 9.3 Mecchanical Reseet SecuRam m Safe Locks can operatee in either An nalog mode or o Digital mo ode. When tthey are pairred with the SafeLogiic Series (EnttryPads with h no LCD screeen or fingerprint reader) the safe locck operates in i analog mode.
ProLogicc B22 Operation Instrructions ortcut Operaations 10.0 Sho 10.1 Add d User: “Meenu/OK” + “1 1” Step 1: Presss the Menu//OK button Step 2: Presss the numbeer "1" button n, the screen prompts: Step 3: Enter a valid Sup per or Managger Code and d press Menu u/OK Step 4: The display d will prompt p you to t enter the new code fo or the user: Step 5: Repeeat the user code Code has beeen successfu ully enrolled. 10.
ProLogicc B22 Operation Instrructions t select th he user you want w to deleete, and finally press Step 4: Presss the “▼” or “▲” to Menu/OK. Step 5: Presss Menu/OK,, the screen prompts: enus 11.
ProLogicc B22 Operation Instrructions Input 9 V Alkaline Battery Workking Currrent 1.5 5A Standby Currrent 80 u uA Batte ery Lifetime 1 Ye ear (1 10 openin ngs/day)) Useer Numb ber 3 Supp port Systtem Android 6.0 and abo ove OS 9.0and above iO B Bluetooth h 4.2 ecaution 13. 0 Pre Operatting enviro onment K Keep away fr from strong g magnetic appliances a or objects when w installling equipm ment. Pllease use th his product within the temperature range off 0°C~49°C.
ProLogicc B22 Operation Instrructions (3) Mounting Screw for Lock * 3 (1) Operration Manual * 1 *Batteryy NOT includ ded *Smartp phone NOT in ncluded C Warning 16.0 FCC difications no ot expressly approved by the party reesponsible fo or compliancce could void Any changes or mod d the userr's authority to operate the equipment. This devvice compliess with part 15 of the FCC Rules.
18.0 Contact us ProLogicc B22 Operation Instrructions Manufacture: c SecuRam Systems, Inc. Address: 3325 Grande Vista Drive Newbury Park, CA 91320 United States @securamsyss.